ACPL-782T-000E Avago Technologies US Inc., ACPL-782T-000E Datasheet - Page 18

OPTO AMP ISOLATION AUTO 8-DIP

ACPL-782T-000E

Manufacturer Part Number
ACPL-782T-000E
Description
OPTO AMP ISOLATION AUTO 8-DIP
Manufacturer
Avago Technologies US Inc.
Series
R2Coupler™r
Datasheet

Specifications of ACPL-782T-000E

Package / Case
8-DIP (0.300", 7.62mm)
Mounting Type
Through Hole
Current - Supply
10.86mA
Operating Temperature
-40°C ~ 125°C
Output Type
Differential
Number Of Circuits
1
Current - Output / Channel
18.6mA
Amplifier Type
Isolation
Voltage - Supply, Single/dual (±)
4.5 V ~ 5.5 V
-3db Bandwidth
100kHz
Voltage - Input Offset
300µV
Forward Current
16 mA
Isolation Voltage
3.75 KV
Mounting Style
Through Hole
Number Of Channels
1
Power Dissipation
600 mW
Bandwidth
100 KHz
Input Offset Voltage
0.3 mV
Operating Supply Voltage
4.5 V to 5.5 V
Supply Current
16 mA
Operating Temperature Range
- 40 C to + 125 C
No. Of Amplifiers
1
Gain Non-linearity Max
2%
Slew Rate
1500V/µs
Supply Voltage Range
4.5V To 5.5V
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Slew Rate
-
Gain Bandwidth Product
-
Current - Input Bias
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACPL-782T-000E
Manufacturer:
AVAGO
Quantity:
5 000
Isolated Temperature Sensing using Thermistor
Thermistor is widely used to measure temperatures in
most systems application. A galvanic isolation between
the potential of the Thermistor and that of the analog-
to-digital is often required when they are mounted in
locations such as high voltage potential, electrically noisy
environments, poorly grounded environments, where
lack of isolation causes either safety or EMI issues.
RL = R1//(R2+R3)=R1(R2+R3)/(R1+R2+R3)
R2 and R3 divides the voltage across RL so that the voltage
fed into ACPL-782T does not exceed +200 mV. The high
impedance characteristic of the input terminals of ACPL-
782T helps in determining those resistors value since one
can select relatively high resistance of R2 and R3 and R1
can be determined easily.
For product information and a complete list of distributors, please go to our web site:
Avago, Avago Technologies, the A logo and R
Data subject to change. Copyright © 2005-2011 Avago Technologies. All rights reserved.
AV02-1565EN - March 23, 2011
2
Coupler™ are trademarks of Avago Technologies in the United States and other countries.
www.avagotech.com
If R2+R3 >> R1, RL ~ R1
Dividing ratio ~ R3/(R2+R3)
As can be seen from the circuit, one might eliminate R1
and RL~(R2+R3) in this case.
An application example with a Thermistor designed for
measuring IGBT’s surface temperatures is shown in Figure
23. Where TH is the thermistor and the RL is a resistor for
linearization. Suitable RL value is determined from the
Thermistor characteristic and the temperature range to
measure. Please note that the RL value is the compound
value of R1, R2 and R3.

Related parts for ACPL-782T-000E