C8051F315-GMR Silicon Laboratories Inc, C8051F315-GMR Datasheet - Page 158

IC 8051 MCU 8K FLASH 28MLP

C8051F315-GMR

Manufacturer Part Number
C8051F315-GMR
Description
IC 8051 MCU 8K FLASH 28MLP
Manufacturer
Silicon Laboratories Inc
Series
C8051F31xr
Datasheets

Specifications of C8051F315-GMR

Core Processor
8051
Core Size
8-Bit
Speed
25MHz
Connectivity
SMBus (2-Wire/I²C), SPI, UART/USART
Peripherals
POR, PWM, WDT
Number Of I /o
25
Program Memory Size
8KB (8K x 8)
Program Memory Type
FLASH
Ram Size
1.25K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 3.6 V
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
28-VQFN Exposed Pad, 28-HVQFN, 28-SQFN, 28-DHVQFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Data Converters
-
C8051F310/1/2/3/4/5/6/7
14.5.2. Master Receiver Mode
Serial data is received on SDA while the serial clock is output on SCL. The SMBus interface generates the
START condition and transmits the first byte containing the address of the target slave and the data direc-
tion bit. In this case the data direction bit (R/W) will be logic 1 (READ). Serial data is then received from the
slave on SDA while the SMBus outputs the serial clock. The slave transmits one or more bytes of serial
data. After each byte is received, ACKRQ is set to ‘1’ and an interrupt is generated. Software must write
the ACK bit (SMB0CN.1) to define the outgoing acknowledge value (Note: writing a ‘1’ to the ACK bit gen-
erates an ACK; writing a ‘0’ generates a NACK). Software should write a ‘0’ to the ACK bit after the last
byte is received, to transmit a NACK. The interface exits Master Receiver Mode after the STO bit is set and
a STOP is generated. Note that the interface will switch to Master Transmitter Mode if SMB0DAT is written
while an active Master Receiver. Figure 14.6 shows a typical Master Receiver sequence. Two received
data bytes are shown, though any number of bytes may be received. Notice that the ‘data byte transferred’
interrupts occur before the ACK cycle in this mode.
158
Interrupt
S
Figure 14.6. Typical Master Receiver Sequence
Received by SMBus
Interface
Transmitted by
SMBus Interface
SLA
R
Interrupt
A
Data Byte
Rev. 1.7
Interrupt
A
S = START
P = STOP
A = ACK
N = NACK
R = READ
SLA = Slave Address
Data Byte
Interrupt
N
P

Related parts for C8051F315-GMR