17-P10-SI E-T-A, 17-P10-SI Datasheet

no-image

17-P10-SI

Manufacturer Part Number
17-P10-SI
Description
SOCKET W/BLADE TERMINALS
Manufacturer
E-T-A
Datasheet

Specifications of 17-P10-SI

Accessory Type
Socket, DIN Rail Mountable
For Use With/related Products
Circuit Breaker; E-1048-8I
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Q1837149B
The Smart Power Relay E-1048-8I.- is a remotely controllable electronic
load disconnecting relay with three functions in a single unit:
The 7 pin INLINE version is designed for use with various E-T-A
terminal blocks, e. g. 17-P10-Si. A choice of current ratings is available
from 1 A through 20 A. An operating voltage range of DC 9...32 V
allows the connection of DC 12 V and DC 24 V loads.
In order to switch and protect loads remotely, it has until now been
necessary to connect several discreet components together:
Now type E-1048-8I. combines all these functions in a single unit,
thus minimising the number of connections in the circuit and
thereby reducing the risk of failures.
Type E-1048-8I. is suited to all applications with DC 12 V or DC 24 V
circuits, where magnetic valves, motors or lamp loads have to be
switched, protected or monitored:
The Power Relay is also suitable for industrial use (process control,
machine-building, engineering) as an electronic coupling relay
between PLC and DC 12 V or DC 24 V load
Issue B
Description
Applications
Features
- an electro-mechanic relay, control cable and integral contact
- an additional protective element (circuit breaker or fuse) for
- a device for current measurement (shunt)
- road vehicles (utility vehicles, buses, special vehicles)
- rail vehicles
- marine industry (ships, boats, yachts etc.)
Integral power electronics provide a wear-resistant switching
function, insensitive to shock and vibration.
Only a fraction of the control power needed by electro-mechanical
relays is required for switching loads. This is important for battery
buffered load circuits which have to remain controlled even with
the generator off line.
The extremely low induced current consumption of less than 1 mA
is absolutely necessary for battery buffered applications.
The load circuit is disconnected in the event of an overload or
short circuit, the trip curve is also suitable for smaller motor loads.
The load circuit is permanently monitored for wire breakage.
Two status outputs for control signal AS and group signal SF
provide status indication. For processing the actual value of the
current flow in a power management system an analogue output
from 0 to 5 V is provided. This voltage signal may also be used as
an input to a control circuit or to switch off the unit by means of
external control in the event of low load current value.
For switching and monitoring loads of 20 A plus it is possible to
connect several units in parallel. Uniform power distribution between
units must be ensured by symmetrical design of the supply cables
(length and cross section).
Coloured label, e. g. red = 10 A, see ordering information.
to close the load circuit
cable or equipment protection
electronic relay
electronic overcurrent protection
status indication
Smart Power Relay E-1048-8I. (INLINE)
www.e-t-a.com
Power supply LINE +
Type
Voltage ratings U
Operating voltage U
Load circuit LOAD
Load output
Max. current rating I
Types of loads
Current rating range I
Induced current consumption
I
Typical voltage drop U
at rated current I
Switching point
Trip time
Current limitation
Temperature disconnection
After trip
Parallel connection of channels for loads of 20 A plus, several units of
Leakage current in OFF
condition
Free-wheeling diode
for connected load
0
Technical Data
of the unit (OFF condition) < 1 mA
(standard curve)
N
N
(at 25 °C) I
S
:
(T U = 25 °C, U S = DC 24 V) (T U = ambient temperature at U N )
N
N
ON
E-1048-8I. INLINE
DC power supply with small R
battery and generator etc.
DC 12 V / DC 24 V
DC 9...32 V
Power MOSFET, high side switching
20 A
resistive, inductive, capacitive, lamp
loads, motors (depending on duration
of inrush current)
1 A...15 A (fixed ratings)
up to 85 °C ambient without load
reduction, 20 A up to 70 °C.
Two basic versions with factory pre-
set ratings:
version 1: 1 A / 2 A / 3 A / 5 A / 7.5 A / 10 A
version 2: 15 A / 20 A
1 A
2 A
3 A
5 A
typically 1.3 x I
(-40 °C...+85 °C: 1.1...1.5 x I
typically 200 ms with switch-on onto
overload and/or load increase on duty
version 1: typically 75 A
version 2: typically 350 A
power transistor > 150 °C
- resettable via external control signal
- reset of supply voltage
identical current ratings may be
connected in parallel. To ensure equal
distribution of current between units,
symmetrical design of the supply feed
is necessary (length and cross section).
version 1: max. 100 μA
version 2: max. 500 μA
integral
version 1: max. 40 A
version 2: max. 100 A
N
(low-high) at control input IN+
50 mV
55 mV
60 mV
80 mV
U
ON
N
I
7.5 A
10 A
15 A
20 A
N
N
90 mV
110 mV
60 mV
60 mV
U
)
i
ON
6 - 23
6

Related parts for 17-P10-SI

17-P10-SI Summary of contents

Page 1

... The 7 pin INLINE version is designed for use with various E-T-A terminal blocks 17-P10-Si. A choice of current ratings is available from 1 A through operating voltage range of DC 9...32 V allows the connection and loads. In order to switch and protect loads remotely, it has until now been ...

Page 2

... EN 61000-6-2 Automotive directive: emitted interference, noise immunity: 72/245/EW6 und 95/54/E6 7 blade terminals 6 0 DIN 46244-A6.3-0.8 contact material CuZn37F37 copper-plated and tin-plated - E-T-A socket type 17-P10-Si (max. load board with 6.3 mm receptacles INLINE: 11 when plugged in 11 including terminals INLINE: Ultramid approx ...

Page 3

... AS SF yellow red control input 1…10 mA IN+ group fault signal max max control signal AS * analogue output 0 … max U( GND * Optionally available: - signal outputs analogue output U(I) E-1048-8I. 17-P10-Si LINE + (2) (2) [2(k)] GND (5) (5) [12] SF (7) (7) [24] U(I) (3) (3) [2(i)] AS (6) (6) [23] IN+ (4) ...

Page 4

... Smart Power Relay E-1048-8I. (INLINE) Typical time/current characteristics (T Version 7.5 A and 10 A (standard 200 ms) 1000 100 10 1 current limitation 0 typ. 1 ... times rated current I Version and 20 A (standard 200 ms) 1000 100 current limitation 0 typ. 1 ... times rated current ° (A) (typ (A) (typ. 350 A) N www.e-t-a.com Issue B ...

Page 5

... E-1048-8I. - Single mounting sockets (with adapter) ( max. load) 17-P10-Si 17-P10-Si-20025 17-P70-Si 17-P70-Si-20025 (retaining clip Y 300 581 11 available on request) polarized blade terminal blade terminal DIN 46244 part 2 DIN 46244-A6.3-0.8 (QC .250) C profile (2xA2.8-0.8) (QC 2x.110) -P10 slot for fitting labels from 6.3 Phoenix, Weidmüller ...

Related keywords