Z8F08200100KIT Zilog, Z8F08200100KIT Datasheet - Page 162

no-image

Z8F08200100KIT

Manufacturer Part Number
Z8F08200100KIT
Description
DEV KIT FOR Z8 ENCORE 4K TO 8K
Manufacturer
Zilog
Series
Z8 Encore!®r
Type
MCUr
Datasheets

Specifications of Z8F08200100KIT

Contents
Evaluation Board, Cable, Power Supply, Software and Documentation
Data Bus Width
8 bit
Interface Type
RS-485
Silicon Manufacturer
Zilog
Core Architecture
Z8 Encore
Silicon Core Number
Z8F0822SJ020
Silicon Family Name
XP F0822
For Use With/related Products
Z8 Encore!™
For Use With
269-4661 - KIT ACC ETHERNET SMART CABLE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
269-3183
PS022517-0508
Caution:
Follow the steps below for setting up the ADC and initiating continuous conversion:
1. Enable the desired analog input by configuring the GPIO pins for alternate function.
2. Write to the ADC Control Register to configure the ADC for continuous conversion.
3. When the first conversion in continuous operation is complete (after 5129 system
4. Thereafter, the ADC writes a new 10-bit data result to {ADCD_H[7:0],
5. To disable continuous conversion, clear the
This disables the digital input and output driver.
The bit fields in the ADC Control Register can be written simultaneously:
clock cycles, plus the 40 cycles for power-up, if necessary), the ADC control logic
performs the following operations:
ADCD_L[7:6]} every 256 system clock cycles. An interrupt request is sent to the
Interrupt Controller when each conversion is complete.
to 0.
In CONTINUOUS mode, ensure that ADC updates are limited by the input
signal bandwidth of the ADC and the latency of the ADC and its digital fil-
ter. Step changes at the input are not seen at the next output from the ADC.
The response of the ADC (in all modes) is limited by the input signal band-
width and the latency.
Write to the ANAIN[3:0] field to select one of the 5 analog input sources.
Set CONT to 1 to select continuous conversion.
Write to the VREF bit to enable or disable the internal voltage reference generator.
Set CEN to 1 to start the conversions.
CEN resets to 0 to indicate the first conversion is complete. CEN remains 0 for all
subsequent conversions in continuous operation.
An interrupt request is sent to the Interrupt Controller to indicate the conversion is
complete.
CONT
bit in the ADC Control Register
Z8 Encore! XP
Product Specification
Analog-to-Digital Converter
®
F0822 Series
149