SXA15-24S05 Emerson Network Power, SXA15-24S05 Datasheet - Page 2

no-image

SXA15-24S05

Manufacturer Part Number
SXA15-24S05
Description
CONVERTER DC/DC 5V OUT 15W SMD
Manufacturer
Emerson Network Power
Series
SXA15r
Type
Isolatedr
Datasheet

Specifications of SXA15-24S05

Rohs Status
RoHS non-compliant
Mfg Application Notes
SXA15 Application Notes
Output
5V
Number Of Outputs
1
Power (watts)
15W
Mounting Type
Surface Mount
Voltage - Input
18 ~ 36V
Package / Case
20-DIP SMD Module
1st Output
5 VDC @ 3A
Size / Dimension
2.00" L x 1.12" W x 0.41" H (50.8mm x 28.4mm x 10.4mm)
Power (watts) - Rated
15W
Operating Temperature
-40°C ~ 70°C
Efficiency
82%
Approvals
CSA, EN, UL
3rd Output
-
2nd Output
-
4th Output
-
SXE15 Series
N N o o t t e e s s
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
International Safety Standard Approvals
TÜV
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Please consult our website for the following items:
DC-DC CONVERTERS
Datasheet © Artesyn Technologies® 2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent
accompany the sale of any such product(s) or information contained herein.
PROTECTION
Short circuit
Overvoltage
TELECOM SPECIFICATION
Central office interface A
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
OUTPUT
POWER
(MAX.)
10.8 W
Measured as per recommended set-up. See Application Note 116 for details.
di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
The SXE15 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 116 for details.
Recommended input fusing is a 2 A HRC 200 V rated fuse.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Measured with external Pi filter. See Application Note 116 for further details.
Start-up into resistive load.
Active low remote on/off is available. Standard product is active high.
Designate with the Suffix ‘-R’ e.g. SXE15-48S05-RJ.
Operating ambient temperatures are specified at natural convection.
Higher operating temperatures are possible with increased airflow.
See Application Note 116 for further details.
SXE15-48S12J below 0.2 A loading. OVP is TVS and 17 V typical.
Signal line assumed < 3 m in length.
A 5% minimum load is required to maintain the output voltage regulation
over all operating conditions for the SXE15-48S12J.
This parameter is calculated at worst case line, load,
temperature and initial settings.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
15 W
15 W
15 W
15 W
UL/cUL 1950 3rd edition. File No. E135734
TÜV Rheinland. File No. 10401-3336-35841. Licence No. 40004290
33-75 Vdc
33-75 Vdc
33-75 Vdc
33-75 Vdc
33-75 Vdc
VOLTAGE
INPUT
S i n g l e o u t p u t
15 Vdc
10.8-15 W High Efficiency DC-DC Converters
2.3 Vdc
3.2 Vdc
4 Vdc
6 Vdc
OVP
(10)
ETS300-132-2, input voltage
VOLTAGE
OUTPUT
and current requirements
1.8 V
2.5 V
3.3 V
12 V
5 V
Latching clamp
CURRENT
OUTPUT
Continuous

(MIN.)
0 A
0 A
0 A
0 A
0 A
Application Note
CURRENT
OUTPUT
(MAX.)
1.25 A
4.5 A
6 A
6 A
3 A
BOTTOM VIEW
SIDE VIEW
TOP VIEW

Longform Data Sheet
0.070 (1.78) MAX
0.394 (10.01)
0.069 (1.74)
0.197 (5.00)
1.181 (30.00)
1.378 (35.00)
1.575 (40.01)
EFFICIENCY
1.150 (29.21)
0.477 (12.11)
(TYP.)
PIN NUMBER
83%
85%
86%
87%
85%
leadframe length
1.812 (46.03)
overall length
1.812 (46.02)
1.905 (48.39)
1.885 (47.88)
10
11
12
1
2
3
4
5
6
7
8
9
PIN CONNECTIONS
0.1%
LINE
0.3%
0.3%
0.1%
0.1%
Non-Skid Retaining Pins,
0.047 (1.18)
REGULATION
0.100 (2.54)
12 places
1.390 (35.31)
ø.050 (ø1.27)
2 Places
0.010 (0.25) MIN
File Name: sxe15s.pdf Rev (02): 08 Dec 2005
FEATURE
Vout +
On/Off
Vout -
Vin +
Vin -
Trim
N/C
N/C
N/C
N/C
N/C
N/C
LOAD
2.0%
1.5%
0.5%
0.5%
0.5%
www.artesyn.com
0.053 (1.36)
0.053 (1.36)
0.394 (10.01)
0.502 (12.75)
All Dimensions in Inches [mm]
ø0.063 (ø1.60)
Recommended Land & Hole Pattern
1
0.130 (3.30)
Tolerence: ±.015 (±.38)
1.181 (30.00)
1.378 (35.00)
NUMBER
SXE15-48S1V8J
SXE15-48S2V5J
SXE15-48S3V3J
0.197 (5.00)
1.575 (40.01)
1.812 (46.02)
SXE15-48S05J
SXE15-48S12J
0.125 (3.18)
0.335 (8.51) MAX
MODEL
0.161 (4.09)
0.063 (1.60)
(8,14,15)
1.200 (30.48)
2