SFH 4050-Z OSRAM Opto Semiconductors Inc, SFH 4050-Z Datasheet
SFH 4050-Z
Specifications of SFH 4050-Z
Q65110A6460
SFH 4050-Z
Related parts for SFH 4050-Z
SFH 4050-Z Summary of contents
Page 1
... Sicherheits- richtlinien der IEC-Normen 60825-1 und 62471 behandelt werden. Typ Bestellnummer Type Ordering Code SFH 4050 Q65110A6460 gemessen bei einem Raumwinkel Ω measured at a solid angle of Ω 2009-05-14 Features • Very small package: (LxWxH 0.65 mm • ...
Page 2
... FSM P tot R thJA 2 2 each R thJS Symbol Symbol λ peak λ centroid Δλ I max I max ϕ SFH 4050 Wert Einheit Value Unit – 40 … + 100 ° 100 180 mW 450 K/W 250 K/W Wert Einheit Value Unit 860 nm 850 ± 80 Grad deg ...
Page 3
... I R Φ e typ bzw. Φ Φ 100 100 100 100 mA TC λ 100 SFH 4050 Wert Einheit Value Unit 0.3 × 0.3 mm² 1.5 (< 1.8) V 2.4 (< 3.0) V μA not designed for reverse operation 50 mW – 0.5 %/K – 0.7 mV/K + 0.3 nm/K ...
Page 4
... Symbol SFH 4050 min max typ f = (ϕ) rel 10˚ 0˚ 1.0 0.8 0.6 0.4 0.2 0 0˚ 20˚ 40˚ 60˚ 80˚ 100˚ 4 Werte Values SFH 4050-Q 6.3 12.5 70 OHF00614 120˚ SFH 4050 Einheit Unit mW/sr mW/sr mW/sr ...
Page 5
... Permissible Pulse Handling = 25 °C, Capability (τ), duty cycle D = parameter OHF02506 1 1 0.8 0.005 0.01 0.02 0.033 0.6 0.05 0.1 0.2 0.4 0 SFH 4050 Max. Permissible Forward Current 450 K thJA 120 mA Ι F 100 80 R thjA OHR00883 = 450 K/W 80 100 ˚C 120 T A ...
Page 6
... Maß (inch) / Dimensions in mm (inch). Gehäuse / Package Epoxydharz, diffus / Epoxy, diffuse Farbe / Colour Farblos / colourless Gehäusemarkierung/ Anode Package marking 2009-05-14 0.125 (0.005) ±0.1 (0.004) Package marking ±0.05 (0.002) 0.65 (0.026) 6 SFH 4050 +0.05 (0.002) -0.03 (0.001) Package marking +0.02 (0.001) -0.05 (0.002) GPLY7036 ...
Page 7
... Maß (inch) / Dimensions in mm (inch). 2009-05-14 Reflow Löten Reflow Soldering 0.8 (0.031) Copper solder pad 0.8 (0.031) 0.8 (0.031) OHAPY606 Reflow Löten Reflow Soldering 0.7 (0.028) 0.8 (0.031) 0.6 (0.024) 0.05 (0.002) Solder stencil aperture Copper solder pad 7 SFH 4050 OHPY3832 ...
Page 8
... Ramp Down 6 K/s (max) 100 s max 200 250 t (nach CECC 00802) (acc. to CECC 00802) Normalkurve standard curve Grenzkurven limit curves 2 K/s 150 200 t SFH 4050 OHLA0687 +0 ˚C -5 ˚C ±5 ˚C +5 ˚C -0 ˚C s 300 OHLY0598 s 250 ...
Page 9
... Life support devices or systems are intended ( implanted in the human body, or (b) to support and/or maintain and sustain human life. If they fail reasonable to assume that the health of the user may be endangered. 2009-05-14 2 with the express written approval of OSRAM OS. 9 SFH 4050 ...