ADUM1301ARWZ Analog Devices Inc, ADUM1301ARWZ Datasheet - Page 20

no-image

ADUM1301ARWZ

Manufacturer Part Number
ADUM1301ARWZ
Description
IC DIGITAL ISOLATOR 3CH 16-SOIC
Manufacturer
Analog Devices Inc
Series
iCoupler®r
Datasheet

Specifications of ADUM1301ARWZ

Propagation Delay
65ns
Inputs - Side 1/side 2
2/1
Number Of Channels
3
Isolation Rating
2500Vrms
Voltage - Supply
2.7 V ~ 5.5 V
Data Rate
1Mbps
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
No. Of Channels
3
Supply Current
1.6mA
Supply Voltage Range
2.7V To 5.5V
Digital Ic Case Style
SOIC
No. Of Pins
16
Operating Temperature Range
-40°C To +105°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM1301ARWZ
Manufacturer:
ADI
Quantity:
28
Part Number:
ADUM1301ARWZ
Manufacturer:
AD
Quantity:
1 000
Part Number:
ADUM1301ARWZ
Manufacturer:
AD
Quantity:
2 000
Part Number:
ADUM1301ARWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADUM1301ARWZ-RL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ADuM1300/ADuM1301
DIN V VDE V 0884-10 (VDE V 0884-10):2006-12 INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The * marking on packages denotes DIN V VDE V 0884-10 approval for 560 V peak working voltage.
Table 11.
Description
Installation Classification per DIN VDE 0110
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method B1
Input-to-Output Test Voltage, Method A
Highest Allowable Overvoltage
Safety-Limiting Values
Insulation Resistance at T
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
After Environmental Tests Subgroup 1
Case Temperature
Side 1 Current
Side 2 Current
After Input and/or Safety Test Subgroup 2
and Subgroup 3
Figure 3. Thermal Derating Curve, Dependence of Safety-Limiting
350
300
250
200
150
100
50
0
Values with Case Temperature per DIN V VDE V 0884-10
0
50
CASE TEMPERATURE (°C)
SIDE #1
S
SIDE #2
100
150
Conditions
V
partial discharge < 5 pC
V
V
Transient overvoltage, t
Maximum value allowed in the event of a failure
(see Figure 3)
V
IORM
IORM
IORM
IO
= 500 V
× 1.875 = V
× 1.6 = V
× 1.2 = V
200
Rev. H | Page 20 of 28
PR
PR
, t
, t
PR
m
m
, 100% production test, t
= 60 sec, partial discharge < 5 pC
= 60 sec, partial discharge < 5 pC
TR
= 10 seconds
RECOMMENDED OPERATING CONDITIONS
Table 12.
Parameter
Operating Temperature (T
Operating Temperature (T
Supply Voltages (V
Supply Voltages (V
Input Signal Rise and Fall Times
1
2
3
Does not apply to ADuM1300W and ADuM1301W automotive grade versions.
Applies to ADuM1300W and ADuM1301W automotive grade versions.
All voltages are relative to their respective ground. See the
and Magnetic Field Immunity
magnetic fields.
m
= 1 sec,
DD1
DD1
, V
, V
DD2
DD2
section for information on immunity to external
A
A
)
)
)
)
1, 3
2, 3
1
2
Symbol
V
V
V
V
T
I
I
R
S1
S2
S
IORM
PR
PR
TR
S
Characteristic
I to IV
I to III
I to II
40/105/21
2
560
1050
896
672
4000
150
265
335
>10
Rating
−40°C to +105°C
−40°C to +125°C
2.7 V to 5.5 V
3.0 V to 5.5 V
1.0 ms
9
DC Correctness
Unit
V peak
V peak
V peak
V peak
V peak
°C
mA
mA
Ω

Related parts for ADUM1301ARWZ