LM83CIMQAX/NOPB National Semiconductor, LM83CIMQAX/NOPB Datasheet - Page 6

IC TEMP SENSOR DIGITAL 16-SSOP

LM83CIMQAX/NOPB

Manufacturer Part Number
LM83CIMQAX/NOPB
Description
IC TEMP SENSOR DIGITAL 16-SSOP
Manufacturer
National Semiconductor
Datasheet

Specifications of LM83CIMQAX/NOPB

Function
Hardware Monitor
Topology
ADC (Sigma Delta), Comparator, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
16-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
*LM83CIMQAX
*LM83CIMQAX/NOPB
LM83CIMQAX

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM83CIMQAX/NOPB
Manufacturer:
NS/TI
Quantity:
1 500
Part Number:
LM83CIMQAX/NOPB
Manufacturer:
TI/德州仪器
Quantity:
20 000
www.national.com
f
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
t
Symbol
SMB
LOW
LOW
HIGH
R,SMB
F,SMB
OF
TIMEOUT
1
2
SU;DAT
3
HD;DAT
4
HD;STA
5
SU;STO
6
SU;STA
BUF
Logic Electrical Characteristics
SMBus DIGITAL SWITCHING CHARACTERISTICS
Unless otherwise noted, these specifications apply for V
pF. Boldface limits apply for T
The switching characteristics of the LM83 fully meet or exceed the published specifications of the SMBus or I
lowing parameters are the timing relationships between SMBCLK and SMBData signals related to the LM83. They are not the
I
,
,
,
,
,
2
C or SMBus bus specifications.
MEXT Cumulative Clock Low Extend Time
SMBus Clock Frequency
SMBus Clock Low Time
SMBus Clock High Time
SMBus Rise Time
SMBus Fall Time
Output Fall Time
SMBData and SMBCLK Time Low for
Reset of Serial Interface (Note 12)
SMBCLK (Clock) Period
Data In Setup Time to SMBCLK High
Data Out Stable after SMBCLK Low
SMBData Low Setup Time to SMBCLK
Low
SMBData High Delay Time after
SMBCLK High (Stop Condition Setup)
SMBus Start-Condition Setup Time
SMBus Free Time
Parameter
A
= T
J
= T
MIN
to T
SMBus Communication
MAX
(Continued)
; all other limits T
CC
10 % to 10 %
90 % to 90%
10% to 90%
90% to 10%
C
I
O
=+3.0 Vdc to +3.6 Vdc, C
L
= 3 mA
= 400 pF,
6
Conditions
A
= T
J
= +25˚C, unless otherwise noted.
L
(load capacitance) on output lines = 80
(Note 6)
Typical
0.3
1
(Note 7)
Limits
TBD
100
250
100
300
100
100
1.3
0.6
0.6
1.3
10
25
10
25
40
10
2
C bus. The fol-
DS101058-4
kHz (max)
kHz (min)
ms (max)
ms (max)
ms (max)
µs (max)
ns (max)
ns (max)
ms (min)
ns (max)
µs (min)
µs (min)
µs (min)
ns (min)
ns (min)
ns (min)
ns (min)
µs (min)
µs (min)
(Limit)
Units