MCP9801-M/MS Microchip Technology, MCP9801-M/MS Datasheet - Page 12

IC SENSOR THERMAL 2.7V 8MSOP

MCP9801-M/MS

Manufacturer Part Number
MCP9801-M/MS
Description
IC SENSOR THERMAL 2.7V 8MSOP
Manufacturer
Microchip Technology

Specifications of MCP9801-M/MS

Package / Case
8-MSOP, Micro8™, 8-uMAX, 8-uSOP,
Output Type
I²C™/SMBus™
Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Register Bank
Sensor Type
Internal
Sensing Temperature
-55°C ~ 125°C
Output Alarm
No
Output Fan
Yes
Voltage - Supply
2.7 V ~ 5.5 V
Operating Temperature
-55°C ~ 125°C
Mounting Type
Surface Mount
Temperature Threshold
Programmable
Full Temp Accuracy
3 C
Digital Output - Bus Interface
I2C, SMBus
Digital Output - Number Of Bits
9 bit to 12 bit
Supply Voltage (max)
5.5 V
Supply Voltage (min)
2.7 V
Description/function
High Accuracy 12-bit Serial Input/Output, Thermal Monitors
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 55 C
Supply Current
400 uA
Ic Output Type
Voltage
Sensing Accuracy Range
± 0.5°C
Temperature Sensing Range
-55°C To +125°C
Supply Voltage Range
2.7V To 5.5V
Resolution (bits)
12bit
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCP9801-M/MS
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
MCP9801-M/MS
0
Company:
Part Number:
MCP9801-M/MS
Quantity:
5 000
MCP9800/1/2/3
FIGURE 4-1:
4.1.5
After the Start condition, each bit of data in
transmission needs to be settled for a time specified by
t
“Serial Interface Timing Specifications” on Page
DS21909D-page 12
SU-DATA
SDA
SCL
Start
before SCL toggles from low-to-high (see
DATA VALID
1
1
Address
Code
2
0
3
0 1 A2 A1 A0
Device Addressing.
Address Byte
4
5
Address
Slave
6
PIC18FXXXX Response
7
R/W
8
A
C
K
9
5).
4.1.6
Each receiving device, when addressed, is obliged to
generate an ACK bit after the reception of each byte.
The master device must generate an extra clock pulse
for ACK to be recognized.
The acknowledging device pulls down the SDA line for
t
the master. SDA also needs to remain pulled down for
t
During read, the master must signal an End-of-Data
(EOD) to the slave by not generating an ACK bit (NAK)
once the last bit has been clocked out of the slave. In
this case, the slave will leave the data line released to
enable the master to generate the Stop condition.
SU-DATA
H-DATA
after a high-to-low transition of SCL.
before the low-to-high transition of SCL from
ACKNOWLEDGE (ACK)
 2010 Microchip Technology Inc.