C8051F313R Silicon Labs, C8051F313R Datasheet - Page 55

no-image

C8051F313R

Manufacturer Part Number
C8051F313R
Description
8-bit Microcontrollers - MCU 8KB 10ADC
Manufacturer
Silicon Labs
Datasheet

Specifications of C8051F313R

Product Category
8-bit Microcontrollers - MCU
Core
8051
Data Bus Width
8 bit
Maximum Clock Frequency
25 MHz
Program Memory Size
8 KB
Data Ram Size
1.25 KB
On-chip Adc
Yes
Operating Supply Voltage
2.7 V to 3.6 V
Package / Case
QFN-28
Mounting Style
SMD/SMT
A/d Bit Size
10 bit
A/d Channels Available
17
Data Rom Size
128 B
Interface Type
I2C, SMBus, SPI, UART
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
25
Number Of Timers
5
On-chip Dac
No
Processor Series
C8051
Program Memory Type
Flash
Factory Pack Quantity
1500
Supply Voltage - Max
3.6 V
Supply Voltage - Min
2.7 V
5.3.2. Tracking Modes
According to Table 5.1, each ADC0 conversion must be preceded by a minimum tracking time for the con-
verted result to be accurate. The AD0TM bit in register ADC0CN controls the ADC0 track-and-hold mode.
In its default state, the ADC0 input is continuously tracked, except when a conversion is in progress. When
the AD0TM bit is logic 1, ADC0 operates in low-power track-and-hold mode. In this mode, each conversion
is preceded by a tracking period of 3 SAR clocks (after the start-of-conversion signal). When the CNVSTR
signal is used to initiate conversions in low-power tracking mode, ADC0 tracks only when CNVSTR is low;
conversion begins on the rising edge of CNVSTR (see Figure 5.4). Tracking can also be disabled (shut-
down) when the device is in low power standby or sleep modes. Low-power track-and-hold mode is also
useful when AMUX settings are frequently changed, due to the settling time requirements described in
Section “5.3.3. Settling Time Requirements” on page
(AD0CM[2:0]=000, 001,010
Timer 1, Timer 3 Overflow
Write '1' to AD0BUSY,
(AD0CM[2:0]=100)
Timer 0, Timer 2,
Figure 5.4. 10-Bit ADC Track and Conversion Example Timing
SAR Clocks
SAR Clocks
SAR Clocks
AD0TM=1
AD0TM=0
011, 101)
AD0TM=1
AD0TM=0
CNVSTR
Low Power
or Convert
Low Power
or Convert
Track or
Convert
A. ADC0 Timing for External Trigger Source
Track or Convert
B. ADC0 Timing for Internal Trigger Source
1
1
Track
2
2
Track
Rev. 1.7
3
3
4
4
1
C8051F310/1/2/3/4/5/6/7
Convert
5
5
56.
2
6
6
3
7
7
4
8
Convert
8
Convert
Convert
5
9
9
6
10 11 12
10 11
7
8
9
13 14
10 11
Low Power Mode
Track
Low Power
Mode
Track
55

Related parts for C8051F313R