Specifications of RXM-GPS-F4-T

Rohs
yes
Frequency Band
1575.42 MHz
Number Of Channels
48
Time To First Fix (cold Start)
32 s
Acquisition Sensitivity
- 159.5 dBm
Horizontal Position Accuracy
3 m
Operating Supply Voltage
1.8 V
Operating Supply Current
56 mA
Interface Type
Serial
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Dimensions
15 mm x 13 mm x 2.2 mm
Minimum Operating Temperature
- 30 C
200 – PowerManagement
This command sets the power mode to Full Power, Adaptive Trickle Power,
or Push-to-Fix mode. The table below contains the values for the following
example to set the receiver to Adaptive Trickle Power mode:
$PLSC,200,2,200,3000,300000,30000*0D
Figure 28: Power Management Command Example
Figure 31: Power Management Command Example
Figure 32 below lists the possible values for the Mode section of this
command.
Figure 32: Power Management Mode Values
1. Default setting is full power; trickle power disabled.
Power Management Command Example
Mode Values
PushToFixPeriod
MaxAcqTime
MaxOffTime
<CR> <LF>
Checksum
LP Interval
OnTime
Name
Mode
MID
Value
0
1
2
3
(1000 – 10000)
$PLSC,200
(200 – 900)
(10 – 7200)
1800000)
Example
300000
Description
Ask the receiver to send the current power mode
Set the receiver to Full Power mode
Set the receiver to Adaptive Trickle Power mode
Set the receiver to Push-to-Fix mode
(1000)
(1000 –
30000
3000
200
*0D
2
Units
sec
ms
ms
ms
ms
27
1
Description
Message ID
See Figure 32
Must be a multiple of 100 (if not, it is
rounded up to the nearest multiple of 100).
Set this to 0 when Mode = 3.
Must be an integer value 1000 and
10000. Set this to 0 when Mode = 3.
When Adaptive Trickle Power is enabled,
this is the maximum allowable time from
the start of a power cycle to the time a valid
position fi x is obtained. If no fi x is obtained
in this time, the receiver is deactivated
for up to MaxOffTime, and a hot start is
commanded when the receiver reactivates.
The integer must be in multiples of
1000ms. There is no upper limit.
The longest period (in mS) for which
the receiver deavtivates due to the
MaxAcqTime timeout. The actual
deactivated period may be less if the
user-specifi ed duty cycle (OnTime /
LpInterval) can be maintained.
The receiver automatically awakens every
Push-to-Fix period to obtain a position fi x,
collect ephemeris (if needed), and calibrate
the real-time clock (RTC) (if needed).
End of message termination