MAX34446EVKIT# Maxim Integrated, MAX34446EVKIT# Datasheet - Page 9

no-image

MAX34446EVKIT#

Manufacturer Part Number
MAX34446EVKIT#
Description
Supervisory Circuits MAX34446 Eval Kit
Manufacturer
Maxim Integrated
Series
MAX34446r
Datasheet

Specifications of MAX34446EVKIT#

Rohs
yes
Number Of Voltages Monitored
4
Output Type
Active High, Active Low, Open Drain, Push-Pull
Watchdog
Watchdog
Supply Voltage - Max
5.5 V
Supply Current (typ)
3 mA
Supply Voltage - Min
2.7 V
Part # Aliases
90-34446#K00
Table 1. PMBus Command Codes (continued)
Note 1: Common commands are shaded. Access through any page results in the same device response.
Note 2: If the device is locked, only the commands listed with “N” can be read. All other commands return FFh if read. Only the
Note 3: In the Flash Stored column, an “N” indicates that this parameter is not stored in flash memory when the STORE_DEFAULT_ALL
Note 4: The factory-set default value that contains the device revision numbers.
Note 5: The factory-set default value for this 8-byte block is 3130313031303130h.
Note 6: The factory-set default value for the complete block of the MFR_NV_FAULT_LOG is FFh.
Note 7: The factory-set default value for the complete block is 00h.
The MAX34446 data logger for power supplies can
monitor voltages for overvoltage and undervoltage, as
well as for overcurrent conditions and overtemperature
conditions. The device constantly checks for user-
programmable thresholds; when these thresholds are
Maxim Integrated
CODE
DAh
DBh
DCh
DDh
D7h
D9h
E0h
E1h
E2h
E3h
EFh
PAGE and MFR_SERIAL commands can be written to. The device unlocks if the upper 4 bytes of MFR_SERIAL match the
data written to the device.
command is executed and the value shown in the Default Value column is automatically loaded upon power-on reset or
when the RST pin is asserted. A “Y” in the Flash Stored column indicates that the currently loaded value in this parameter
is stored in flash memory when the STORE_DEFAULT_All command is executed and is automatically loaded upon power-
on reset or when the RST pin is asserted and the value shown in the Default Value column is the value when shipped
from the factory. “FIXED” in the Flash Stored column means this value is fixed at the factory as a ROM value and cannot
be changed.
MFR_VOUT_MIN
MFR_FAULT_RESPONSE
MFR_FAULT_RETRY
MFR_PG_DELAY
MFR_NV_FAULT_LOG
MFR_TIME_COUNT
MFR_POUT_PEAK
MFR_POUT_AVG
MFR_IOUT_AVG
MFR_TEMPERATURE_AVG
MFR_SYNC_CONFIG
COMMAND NAME
Detailed Description
Block Read
Block Read
R/W Word
R/W Word
R/W Word
R/W Word
R/W Word
R/W Word
R/W Word
R/W Word
R/W Byte
TYPE
PMBus Power-Supply Data Logger
PAGE
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
0–3
R
(NOTE 1)
PAGE
4, 5, 6
R/W
R/W
R/W
R/W
R/W
R
exceeded, the device logs the recent real-time operating
conditions in nonvolatile flash memory. The device can
monitor up to four voltages or currents, and can monitor
three temperature sensors. See the
Circuit/Block Diagram
PAGE
R/W
R/W
255
R
NO. OF
BYTES
255
2
1
2
2
4
2
2
2
2
2
for more details.
(NOTE 2)
LOCKED
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
MAX34446
(NOTE 3)
STORED
FLASH
Typical Application
N
N
N
N
N
Y
Y
Y
Y
Y
Y
DEFAULT
(NOTE 3)
(Note 6)
(Note 7)
VALUE
7FFFh
0000h
0000h
0000h
0000h
0000h
0000h
0000h
00h