Z8F041APH020SG2156 ZiLOG, Z8F041APH020SG2156 Datasheet - Page 145

no-image

Z8F041APH020SG2156

Manufacturer Part Number
Z8F041APH020SG2156
Description
8-bit Microcontrollers - MCU 4K FLASH 1K RAM 128B NVDS
Manufacturer
ZiLOG
Datasheet

Specifications of Z8F041APH020SG2156

Rohs
yes
Core
eZ8
Processor Series
Z8F041xx
Data Bus Width
8 bit
Maximum Clock Frequency
20 MHz
Program Memory Size
4 KB
Data Ram Size
1 KB
On-chip Adc
Yes
Operating Supply Voltage
2.7 V to 3.6 V
Operating Temperature Range
- 40 C to + 105 C
Package / Case
PDIP-20
Mounting Style
Through Hole
A/d Bit Size
10 bit
A/d Channels Available
8
Interface Type
UART
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Number Of Programmable I/os
17
Number Of Timers
2
Program Memory Type
Flash
Supply Voltage - Max
3.6 V
Supply Voltage - Min
2.7 V
PS022827-1212
Interrupts
3. Write to the ADC Control Register 0 to configure the ADC for continuous conversion.
4. When the first conversion in continuous operation is complete (after 5129 system
5. The ADC writes a new data result every 256 system clock cycles. For each completed
6. To disable continuous conversion, clear the CONT bit in the ADC Control Register to 0.
The ADC is able to interrupt the CPU when a conversion has been completed. When the
ADC is disabled, no new interrupts are asserted; however, an interrupt pending when the
ADC is disabled is not cleared.
The bit fields in the ADC Control Register may be written simultaneously:
clock cycles, plus the 40 cycles for power-up, if necessary), the ADC control logic
performs the following operations:
conversion, the ADC control logic performs the following operations:
Write to
plus unbuffered or buffered mode.
Write the
voltage reference level or to disable the internal reference. The
contained in the ADC Control Register 0.
Write to the
(different input pins available depending on the device).
Set CONT to 1 to select continuous conversion.
If the internal VREF must be output to a pin, set the
voltage reference must be enabled in this case.
Write the
voltage reference level or to disable the internal reference. The
contained in ADC Control/Status Register 1.
Set CEN to 1 to start the conversions.
CEN resets to 0 to indicate the first conversion is complete. CEN remains 0 for all
subsequent conversions in continuous operation
An interrupt request is sent to the Interrupt Controller to indicate the conversion is
complete
Writes the 13-bit two’s complement result to {ADCD_H[7:0], ADCD_L[7:3]}
Sends an interrupt request to the Interrupt Controller denoting conversion com-
plete
BUFMODE
REFSELL
REFSELH
ANAIN[3:0]
P R E L I M I N A R Y
[2:0] to select SINGLE-ENDED or DIFFERENTIAL mode,
bit of the pair {
bit of the pair {
field to select from the available analog input sources
REFSELH, REFSELL
REFSELH
Z8 Encore! XP
,
REFSELL
REFEXT
Product Specification
} to select the internal
} to select the internal
bit to 1. The internal
®
F082A Series
REFSELL
REFSELH
Operation
bit is
bit is
128

Related parts for Z8F041APH020SG2156