H3DK OMRON [Omron Electronics LLC], H3DK Datasheet - Page 9

no-image

H3DK

Manufacturer Part Number
H3DK
Description
Solid-state Timers
Manufacturer
OMRON [Omron Electronics LLC]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
H3DK-A2ET380-440VAC
Manufacturer:
OMRON
Quantity:
5
Part Number:
H3DK-FA
Manufacturer:
OMRON
Quantity:
2
Part Number:
H3DK-FAC/DC24-240
Manufacturer:
OMRON
Quantity:
11
Part Number:
H3DK-HBSAC/DC24-240
Manufacturer:
OMRON
Quantity:
46
Part Number:
H3DK-HDS
Manufacturer:
OMRON
Quantity:
1
■ Timing Charts
Note 1.The reset time is 0.1 s min. Make sure the signal input time is 0.05 s or longer.
Note 2.“t” is the set time. “t−a” is a time that is less that the set time.
• There is no start input with the H3DK-S. Timer operation starts when the power is turned ON.
• There is no instantaneous output with the H3DK-@1.
A: ON Delay
B: Flicker OFF Start
B2: Flicker ON start
C: Signal ON/ OFF Delay
Instantaneous contacts: NC
(21 and 22)
Instantaneous contacts: NO
(21 and 24)
Instantaneous contacts: NO
(21 and 24)
Instantaneous contacts: NO
(21 and 24)
Instantaneous contacts: NC
(21 and 22)
Instantaneous contacts: NC
(21 and 22)
Instantaneous contacts: NC
(21 and 22)
Instantaneous contacts: NO
(21 and 24)
Time-limit contacts: NO
(output indicator)
15 and 18 (25 and 28)
Time-limit contacts: NO
(output indicator)
15 and 18 (25 and 28)
Time-limit contacts: NO
(output indicator)
15 and 18 (25 and 28)
Time-limit contacts: NO
(output indicator)
15 and 18 (25 and 28)
Time-limit contacts: NC
15 and 16 (25 and 26)
Time-limit contacts: NC
15 and 16 (25 and 26)
Time-limit contacts: NC
15 and 16 (25 and 26)
Time-limit contacts: NC
15 and 16 (25 and 26)
Power (A1 and A2)
Power (A1 and A2)
Power (A1 and A2)
Power (A1 and A2)
Start (B1 and A1)
Start (B1 and A1)
Start (B1 and A1)
Start (B1 and A1)
Power indicator
Power indicator
Power indicator
Power indicator
t
t
t
t
t
t
t
t−a
t−a
t−a
t
t
t
t
t
t−a
t
t
t
t
t−a
t−a
t−a
Basic Operation
Basic Operation
Basic Operation
Start input
Start input
Start input
Start input
Basic Operation
Output
Output
Output
Power
Power
Output
Power
Power
* To start with the power supply, connect start input
** The start input is ignored while the Timer is in
* To start with the power supply, connect start input
** The start input is ignored while the Timer is in
* For power ON-delay operation, connect start input
** The start input is ignored while the Timer is in
* The start input is valid while the Timer is in
*
*
terminals B1 and A1. The Timer starts operating
as soon as the power turns ON.
operation.
*
terminals B1 and A1. The Timer starts operating
as soon as the power turns ON.
operation.
terminals B1 and A1. The Timer starts operating
as soon as the power turns ON.
operation.
*
operation.
**
**
**
Timing
Timing
Timing
H3DK-M/H3DK-S
Timing
Timing
Timing
Timing
Timing
Timing
Timing
Timing
Timing
Timing
9