0809-0012 EnerSys, 0809-0012 Datasheet

BATT CYCLON SLA 6V 5.0AH

0809-0012

Manufacturer Part Number
0809-0012
Description
BATT CYCLON SLA 6V 5.0AH
Manufacturer
EnerSys
Series
Cyclon®r
Type
Sealed Lead Acid Batteriesr
Datasheets

Specifications of 0809-0012

Voltage - Rated
6V
Capacity
5.0Ah
Size / Dimension
5.48" Dia x 2.12" H (139.2mm x 53.8mm)
Termination Style
Spade, .250" (6.3mm)
Rechargeability
Yes
Weight
2.2 lbs (997.9g)
Output Voltage
6 V
Chemistry
Lead Acid
Rechargeable/non-rechargeable
Rechargeable
Battery Capacity
5 Ah
Battery Voltage
6V
Battery Technology
Pure Lead
External Height
76.7mm
External Width
53.8mm
External Depth
139.2mm
Battery Terminals
Tab
Height
3.02"
Rohs Compliant
NA
Lead Free Status / RoHS Status
Lead free by exemption / RoHS compliant by exemption
Other names
842-1010

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
0809-0012
Manufacturer:
RENATA
Quantity:
4 000
SELECTION GUIDE
1973 TO 2008
Publication No: US-CYC-SG-003 - June 2008

Related parts for 0809-0012

0809-0012 Summary of contents

Page 1

Publication No: US-CYC-SG-003 - June 2008 SELECTION GUIDE 1973 TO 2008 ...

Page 2

... EnerSys In addition to our manufacturing capability, EnerSys is proud to provide its customers with the following services: is the Applications Batteries from the EnerSys “pure lead” family are used in a wide variety of standby and portable/cyclic applications including those in: Value-Added Services ® Customized manufacturing design ...

Page 3

... TABLE OF CONTENTS Company background EnerSys ® .................................................................................................................... 2 Services and applications ......................................................................................... 2 Features and benefits ............................................................................................... 5 Technical information Capacity as a function of temperature ..................................................................... 7 State of charge .......................................................................................................... 7 Storage time as a function of temperature ............................................................... 7 Charging recommendations ...................................................................................... 7 CYCLON ® Battery Single Cells ® CYCLON product family .......................................................................................... 8 CYCLON ® battery alternate configurations .............................................................. 9 CYCLON ® ...

Page 4

... CYCLON battery provides leak-proof operation in any position. Steel can enclosure The CYCLON battery’s metal outer jacket offers extreme shock, vibration, temperature, and flammability protection. 4 www.enersys.com ® battery plates are extremely thin, One-piece plastic cover Direct thru-the-wall intercell connections ...

Page 5

... This is 50% to 100% overall better performance for your energy dollar. 7. Rugged construction - Due to their strong external packaging and internal pure lead composition, EnerSys products can withstand not only extreme temperatures but also harsh usage. CYCLON battery Single Cells are available housed in cases constructed of UL 94V-0 rated material ...

Page 6

... As a result, our batteries are more resistant to venting and dryout from continuous overcharge in standby applications. 8. Fastest recharge - EnerSys pure lead chemistry allows our batteries and cells to offer the highest recharge efficiency of any sealed-lead battery on the market. With pure lead, you can achieve a 95% ...

Page 7

... Battery Single Cells & Monoblocs ® 2.17 2.14 2.11 2.08 2.05 2.02 1.99 1.96 1.93 1. State of Charge, % Storage time as a function of temperature for CYCLON & Monoblocs (fully charged cell) www.enersys.com ® Battery Single Cells & RATE C/5 RATE 100 ® Battery Single Cells ...

Page 8

... Part Monobloc Number mΩ @ 25°C charged cell D cell 2.5Ah 0819-0012 X cell 5.0Ah 0809-0012 E cell 8.0Ah 0859-0012 8 www.enersys.com Most current waveforms are not pure DC nor are they pure sine waves. Therefore, consult the EnerSys Application Support Department for assistance when evaluating the ® ...

Page 9

... Trapezoid BC Quick Disconnect Terminals AMP series 250 Faston terminals are available for BC batteries. Connection Terminations A wide variety of terminations are offered. For recommendations or to specify; contact your EnerSys Territory Manager or battery assembler. Fusible Links Flat Pack Specify your requirement. Dimensions .187” x .025” ...

Page 10

... CC should consult the EnerSys UL Recognized Component. Meets UL 1989 Caution: Batteries contain toxic materials (Pb and H2SO4) • Avoid short circuit • Do not charge in gas-tight container Sealed-lead rechargeable battery must be recycled or disposed of properly. Contact EnerSys 10 www.enersys.com Varying lead lengths and gauges are also available; ...

Page 11

... CYCLON ® Battery 12 Volt 1x6 ABS Case Product Number 0810-0016 0810-0075 0800-0016 0800-0072 All dimensions, excluding weight, are maximum *Due to special assembly, consult the EnerSys www.enersys.com Battery Single Cell standard assemblies Length Width Description in. mm in. 2.5Ah D Dbl. Slot 4.05 102.9 1 ...

Page 12

... All dimensions, excluding weight, are maximum UL Recognized Component. Meets UL 1989 Caution: Batteries contain toxic materials (Pb and H2SO4) • Avoid short circuit • Do not charge in gas-tight container Sealed-lead rechargeable battery must be recycled or disposed of properly. Contact EnerSys 12 www.enersys.com DURATION 10 min 15 min ...

Page 13

... J cell 0.32 8.1 0.74 18.8 0.312 7.92 CYCLON Battery BC Single Cell mechanical specifications (F, G & Maximum) ® Products in cell 0.65 16.5 1.30 33.0 22 www.enersys.com DIMENSIONS in. mm in. mm in. mm 22° 0.27 6.9 0.025 0.64 2.41 61.2 22° 0.27 6.9 ...

Page 14

... CYCLON CYCLON 14 www.enersys.com Battery Single Cell constant current (CC) discharge ® Battery Single Cell constant power (CP) discharge ® Publication No: US-CYC-SG-003 - June 2008 ...

Page 15

... CC should consult the EnerSys ® Application Support Department. UL Recognized Component. Meets UL 1989 Caution: Batteries contain toxic materials (Pb and H2SO4) • Avoid short circuit • Do not charge in gas-tight container Sealed-lead rechargeable battery must be recycled or disposed of properly. Contact EnerSys www.enersys.com DURATION 15 min 30 min ...

Page 16

... CYCLON CYCLON Product Number CYCLON Product Number 0819-0012 0809-0012 0859-0012 CYCLON Product Number 0819-0030 0809-0030 0859-0030 CYCLON Product Number 0819-0016 0809-0016 0859-0016 All dimensions, excluding weight, are maximum One-piece plastic cover High integrity terminal seal One-piece plastic case Lead grids 16 www.enersys.com Battery 4V/6V Monobloc standard assemblies ® ...

Page 17

... Battery 6V Monobloc mechanical specifications (A, B & maximum) Products A B in Monobloc 2.75 69.9 4.48 113.8 X Monobloc 3.02 76.7 5.48 139.2 E Monobloc 4.00 101.6 5.48 139.2 D Monobloc X & E Monobloc www.enersys.com DIMENSIONS in. mm in. mm in. 1.81 46.0 .61 15.5 1.23 2.12 53.8 .73 18.5 1.45 2.13 54.1 ...

Page 18

... Monobloc constant current (CC) curves to 1.67Vpc 4V/6V Monobloc constant power (CP) curves to 1.67Vpc 18 www.enersys.com Publication No: US-CYC-SG-003 - June 2008 ...

Page 19

... Xsc, shrink wrap, leads 0800-0016 1x6 Xsc, double slot, ABS case 0800-0072 1x6 Xsc, single slot, ABS case, leads 0800-0114 2x3 Xsc, double slot, shrink wrap 0800-0115 2x3 Xsc, shrink wrap, leads www.enersys.com PERFORMANCE VOLTAGE 10 Hr RATE SPECIFICATIONS 2V 2.5Ah Page ...

Page 20

... BCsc, double slot, copper strap MONOBLOC (mb) PART DESCRIPTION NUMBER 0819-0010 D Monobloc (Dmb) 0809-0010 X Monobloc (Xmb) 0859-0010 E Monobloc (Emb) 0819-0012 D Monobloc (Dmb) 0809-0012 X Monobloc (Xmb) 0859-0012 E Monobloc (Emb) MONOBLOC STANDARD BATTERY DESIGNS PART DESCRIPTION NUMBER 0819-0016 1x6 Dmb 0819-0030 2x3 Dmb 0809-0016 ...

Related keywords