h8s-2111b Renesas Electronics Corporation., h8s-2111b Datasheet - Page 401

no-image

h8s-2111b

Manufacturer Part Number
h8s-2111b
Description
Renesas 16-bit Single-chip Microcomputer H8s Family / H8s/2100 Series
Manufacturer
Renesas Electronics Corporation.
Datasheet
This LSI has an on-chip LPC interface.
The LPC performs serial transfer of cycle type, address, and data, synchronized with the 33 MHz
PCI clock. It uses four signal lines for address/data, and one for host interrupt requests. This LPC
module supports only I/O read cycle and I/O write cycle transfers.
It is also provided with power-down functions that can control the PCI clock and shut down the
host interface.
15.1
• Supports LPC interface I/O read cycles and I/O write cycles
• Has three register sets comprising data and status registers
• Supports SERIRQ
• Eleven interrupt sources
IFHSTL0A_020020040200
 Uses four signal lines (LAD3 to LAD0) to transfer the cycle type, address, and data.
 Uses three control signals: clock (LCLK), reset (LRESET), and frame (LFRAME).
 The basic register set comprises three bytes: an input register (IDR), output register (ODR),
 Channels 1 and 2 have fixed I/O addresses of H'60/H'64 and H'62/H'66, respectively. A fast
 The I/O address can be set for channel 3. Sixteen bidirectional data register bytes can be
 Host interrupt requests are transferred serially on a single signal line (SERIRQ).
 On channel 1, HIRQ1 and HIRQ12 can be generated.
 On channels 2 and 3, SMI, HIRQ6, and HIRQ9 to HIRQ11 can be generated.
 Operation can be switched between quiet mode and continuous mode.
 The CLKRUN signal can be manipulated to restart the PCI clock (LCLK).
 The LPC module can be shut down by inputting the LPCPD signal.
 Three pins, PME, LSMI, and LSCI, are provided for general input/output.
and status register (STR).
A20 gate function is also provided.
manipulated in addition to the basic register set.
Features
Section 15 Host Interface (LPC)
Rev. 1.00, 05/04, page 367 of 544

Related parts for h8s-2111b