wm8805 Wolfson Microelectronics plc, wm8805 Datasheet - Page 23

no-image

wm8805

Manufacturer Part Number
wm8805
Description
8 1 Digital Interface Transceiver With Pll
Manufacturer
Wolfson Microelectronics plc
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
wm8805GEDS
Manufacturer:
WM
Quantity:
20 000
Part Number:
wm8805GEDS/RV
0
w
Production Data
Table 21 User Mode PLL_K and PLL_N Multiplier Control
PLL CONFIGURATION
The PLL performs a configurable frequency multiplication of the input clock signal (f
multiplication factor of the PLL (denoted by ‘R’) is variable and is defined by the relationship: R = (f
f
The multiplication factor is set using register bits PLL_N and PLL_K (refer to Table 21). The
multiplication effect of both the N and K multipliers are additive (i.e. if N is configured to provide a
multiplication factor of 8 and K is configured to provide a multiplication factor of 0.192, the overall
multiplication factor is 8 + 0.192 = 8.192).
In order to choose and configure the correct values for PLL_N and PLL_K, multiplication factor R
must first be calculated. Once value R is calculated, the value of PLL_N is the integer (whole
number) value of R, ignoring all digits to the right of the decimal point. For example, if R is calculated
to be 8.196523, PLL_N is simply 8.
Once PLL_N is calculated, the PLL_K value is simply the integer value of (2
example, if R is 8.196523 and PLL_N is 8, PLL_K is therefore (2
(ignoring all digits to the right of the decimal point).
Note: the PLL is designed to operate with best performance (shortest lock time and optimum
stability) when f
in the range 5 ≤ PLL_N ≤ 13. Do not use values outwith this range and it is recommended that the
chosen value of PLL_N is as close to 8 as possible for optimum performance.
An output divider is provided to allow the f
as the source for the MCLK, CLKOUT or S/PDIF transmitter. The divider output is configurable and is
set by the FREQMODE bits. The PLL is also equipped with a pre-scale divider which offers
frequency divide by one or two before the OSCCLK signal is fed to the PLL. Please refer to Table 22
for details.
1
).
REGISTER
ADDRESS
PLL1
PLL2
PLL3
PLL4
03h
04h
05h
06h
R3
R4
R5
R6
2
is between 90 and 100MHz and PLL_N is 8. However, acceptable PLL_N values lie
BIT
7:0
7:0
5:0
3:0
PLL_K[21:16]
PLL_K[15:8]
PLL_N[3:0]
PLL_K[7:0]
LABEL
2
clock signal to be divided to a frequency suitable for use
DEFAULT
00100001
11111101
00110110
0111
Fractional (K) part of PLL frequency
ratio (R).
Value K is one 22-digit binary
number spread over registers R3,
R4 and R5 as shown.
Note: PLL_K must be set to
specific values when the S/PDIF
receiver is used. Refer to S/PDIF
Receiver clocking section for
details.
Integer (N) part of PLL frequency
ratio (R).
Use values in the range 5 ≤ PLL_N
≤ 13 as close as possible to 8
Note: PLL_N must be set to
specific values when the S/PDIF
receiver is used. Refer to S/PDIF
Receiver clocking section for
details.
22
(8.196523-8)), which is 824277
DESCRIPTION
PD, Rev 4.5, March 2009
22
(R-PLL_N)). For
WM8805
1
). The
2
23
÷

Related parts for wm8805