xr16c2850im Exar Corporation, xr16c2850im Datasheet - Page 36
xr16c2850im
Manufacturer Part Number
xr16c2850im
Description
Dual Uart With Tx And Rx Fifo Counters, 128 Bytes Of Fifos And Automatic Rs-485 Half Duplex Control
Manufacturer
Exar Corporation
Datasheet
1.XR16C2850IM.pdf
(51 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
XR16C2850IM
Manufacturer:
EXAR
Quantity:
12
Part Number:
XR16C2850IM
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
Company:
Part Number:
xr16c2850im-F
Manufacturer:
XILINX
Quantity:
229
Company:
Part Number:
xr16c2850im-F
Manufacturer:
Exar Corporation
Quantity:
10 000
Part Number:
xr16c2850im-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
XR16C2850
2.97V TO 5.5V DUAL UART WITH 128-BYTE FIFOS
EFR[5]: Special Character Detect Enable
•
•
EFR[6]: Auto RTS Flow Control Enable
RTS# output may be used for hardware flow control by setting EFR bit-6 to logic 1. When Auto RTS is
selected, an interrupt will be generated when the receive FIFO is filled to the programmed trigger level and
RTS de-asserts to a logic 1 at the next upper trigger level or hysteresis level. RTS# will return to a logic 0 when
FIFO data falls below the next lower trigger level. The RTS# output must be asserted (logic 0) before the auto
RTS can take effect. RTS# pin will function as a general purpose output when hardware flow control is
disabled.
•
•
EFR[7]: Auto CTS Flow Control Enable
Automatic CTS Flow Control.
•
•
These registers are used as the programmable software flow control characters xoff1, xoff2, xon1, and xon2.
For more details, see
4.20
Logic 0 = Special Character Detect Disabled (default).
Logic 1 = Special Character Detect Enabled. The UART compares each incoming receive character with
data in Xoff-2 register. If a match exists, the receive data will be transferred to FIFO and ISR bit-4 will be set
to indicate detection of the special character. Bit-0 corresponds with the LSB bit of the receive character. If
flow control is set for comparing Xon1, Xoff1 (EFR [1:0]= ‘10’) then flow control and special character work
normally. However, if flow control is set for comparing Xon2, Xoff2 (EFR[1:0]= ‘01’) then flow control works
normally, but Xoff2 will not go to the FIFO, and will generate an Xoff interrupt and a special character
interrupt, if enabled via IER bit-5.
Logic 0 = Automatic RTS flow control is disabled (default).
Logic 1 = Enable Automatic RTS flow control.
Logic 0 = Automatic CTS flow control is disabled (default).
Logic 1 = Enable Automatic CTS flow control. Data transmission stops when CTS# input de-asserts to logic
1. Data transmission resumes when CTS# returns to a logic 0.
Software Flow Control Registers (XOFF1, XOFF2, XON1, XON2) - Read/Write
Table
6.
36
xr