ULTRA-LOW CURRENT CONSUMPTION 150 mA VOLTAGE REGULATOR WITH BUILT-IN HIGH-ACCURACY VOLTAGE DETECTOR AND RESET INPUT FUNCTION
Rev.1.1
2. 3 Hysteresis width (V
2. 4 Delay time (t
2. 5 Through-type current
The hysteresis width is the difference between the detection voltage and the release voltage. Setting the
hysteresis width prevents malfunction caused by noise on the input voltage. The hysteresis width is internally
fixed and varies depending on the product type (refer to Table 2).
The delay time (t
voltage (+V
The internal delay type products (S-1702Axx, Bxx, Cxx, Dxx, Exx, Fxx, Gxx, Hxx, Jxx, Kxx) have delay time which
is internally fixed.
In external delay type products (S-1702Lxx, Mxx, Nxx, Pxx), the delay time (t
capacitance value of the capacitor (C
For how to set the delay time (t
This is the current that flows instantaneously when the voltage detector detects and releases a voltage.
A large through-type current flows in CMOS output products (S-1702xBx, xCx, xEx, xFx, xHx, xJx).
A small through-type current flows in Nch open drain products (S-1702xAx, xDx, xGx).
_00
Remark This is the case when the regulator output voltage (V
DET
+V
), until the detector output voltage (V
DET
D
)
D
V
) is a period from the input voltage flowing to the detector block has exceeded the release
HYS
V
)
OUT
D
), refer to “3. 2 Delay circuit” in “3. Detector block” in “ Operation”.
t
D
D
) connected between the CD (RESX) and VSS pins.
Seiko Instruments Inc.
When t
t
D
Figure 21
D
= 90 µs
DOUT
) inverts.
V
DOUT
OUT
When t
t
) is monitored by the detector.
D
= 30 ms
D
) can be changed by controlling the