peb20954 Infineon Technologies Corporation, peb20954 Datasheet - Page 74
peb20954
Manufacturer Part Number
peb20954
Description
Smart Integrated Digital Echo Canceller Sidec
Manufacturer
Infineon Technologies Corporation
Datasheet
1.PEB20954.pdf
(132 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
peb20954HT
Manufacturer:
MITSUMI
Quantity:
510
Company:
Part Number:
peb20954HT-V1.1
Manufacturer:
SIEMENS
Quantity:
16
Company:
Part Number:
peb20954HTV1.1
Manufacturer:
INFINEON
Quantity:
1 831
Company:
Part Number:
peb20954HV1.3
Manufacturer:
INFINEON
Quantity:
1 831
Preliminary Data Sheet
WDG2[7:0] (Addr.: 03H) Watchdog 2
WDG2[7:0]
WDG3[7:0] (Addr.: 04H) Watchdog 3
WDG3[7:0]
PCMCTRL[3:0] (Addr.: 06H) PCM Bypass and loop Control, write protected,
Reset value = 00H
SRLOOP
RSLOOP
RBYPASS
SBYPASS
Note: If SRLOOP=’1’ and RSLOOP=’1’ only RSLOOP becomes active.
CONFPCM[7:0] (Addr.: 30H): Global Configuration of PCM outputs, write protected,
Reset value = 03H
NLPITU
NLPMOD
SOATTEN
WDG2[7] WDG2[6] WDG2[5] WDG2[4] WDG2[3] WDG2[2] WDG2[1] WDG2[0]
WDG3[7] WDG3[6] WDG3[5] WDG3[4] WDG3[3] WDG3[2] WDG3[1] WDG3[0]
NLP
ITU
-
MOD
NLP
-
For watchdog test: Must be written with the defined value 99H as
the second of the three watchdog registers within 2 seconds
For watchdog test: Must be written with the defined value 1DH as
the last of the three watchdog registers within 2 seconds
’1’: NLP comfort noise according to ITU
’0’: NLP comfort noise subjective
only if NLPITU = ’1’:
’1’: Attenuation of send path output enabled and controlled by echo
’1’: Enables the internal loop from SO signal to RI signal
’0’: Normal operation
’1’: Enables the internal loop from RO signal to SI signal
’0’: Normal operation
’1’: Bypasses the RI input directly to the RO output
’0’: Normal operation
’1’: Bypasses the SI input directly to the SO output
’0’: Normal operation
SOATT
EN
-
SOATT
MOD
-
74
’1’:output signal is band limited noise
’0’:output signal is zero, i.e. line is dead
ROATT
LOOP
SR
EN
ROATT
LOOP
MOD
RS
Register Description
BYPASS
DYN
SUB
R
PEB 20954
PEF 20954
BYPASS
INVERR
SIGN
S
04.99