3.6 Power Sequence
Note:
(1) T4=0 : concern for residual pattern before BLU turn off.
(2) T6 : voltage of VDD must decay smoothly after power-off. (customer system decide this value)
©Copyright AU Optronics Corp.
2009 All Rights Reserved.
No Reproduction and Redistribution Allowed
Apply the lamp voltage within the LCD operating range. When the backlight turns on before the LCD
operation or the LCD turns off before the backlight turns off, the display may momentarily become abnormal.
Caution: The above on/off sequence should be applied to avoid abnormal function in the display. In case of
handling, make sure to turn off the power when you plug the cable into the input connector or pull the cable
out of the connector.
Caution: The above on/off sequence should be applied to avoid abnormal function in the display. In case of
handling, make sure to turn off the power when you plug the cable into the input connector or pull the cable
out of the connector.
Parameter
t1
t2
t3
t4
t5
t6
t7
Min.
300
500
0.4
0.1
0
--
0
*1
T546HW01 V1
Values
Typ.
--
--
--
--
--
--
--
www.DataSheet.co.kr
Max.
--
30
--
--
--
--
--
*2
Unit
ms
ms
ms
ms
ms
ms
ms