ADIS16203 Analog Devices, Inc., ADIS16203 Datasheet - Page 17

no-image

ADIS16203

Manufacturer Part Number
ADIS16203
Description
Programmable 360 Inclinometer
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADIS16203/PCBZ
Manufacturer:
Analog Devices Inc
Quantity:
135
Part Number:
ADIS16203CCCZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ALM_MAG2 Register Definition
Address
0x23, 0x22
1
2
The ALM_MAG2 register contains the threshold level for Alarm 2.
The contents of this register are nonvolatile.
Table 13. ALM_MAG2 Bit Designations
Bit
15
14
13:0
ALM_SMPL2 Register Definition
Address
0x27, 0x26
1
The ALM_SMPL2 register contains the sample period information
for Alarm 2, when it is set for ROC alarm monitoring. The ROC
alarm function averages the change in the output variable over the
specified number of samples and compares this change directly to
the values specified in the ALM_MAG2 register. The contents of this
register are nonvolatile.
Table 14. ALM_SMPL2 Bit Designations
Bit
15:8
7:0
ALM_CTRL Register Definition
Address
0x29, 0x28
1
The ALM_CTRL register contains the alarm control variables.
Default is valid only until the first register write cycle.
Format is established by source of monitored data.
Default is valid only until the first register write cycle.
Default is valid only until the first register write cycle.
Description
Greater than Active Alarm Bit.
Not used.
Data Bits. This number can be either twos complement
or straight binary. The format is set by the value being
monitored by this function.
Description
Not used
Data bits
1: Alarm is active for an output greater than
ALM_MAG2 register setting.
0: Alarm is active for an output less than
ALM_MAG2 register setting.
Default
0x0000
Default
0x0000
Default
0x0000
1
1
1
Format
N/A
Format
Binary
Format
N/A
2
Access
Access
Access
R/W
R/W
R/W
Rev. 0 | Page 17 of 28
Table 15. ALM_CTRL Bit Designations
Bit
15
14:12
11
10:8
7:6
5
4
3
2
1
0
Value
000
001
010
011
100
101
110
111
000
001
010
011
100
101
110
111
Description
Rate of Change (ROC) Enable for Alarm 2
Alarm 2 Source Selection
Rate of Change (ROC) Enable for Alarm 1
Alarm 1 Source Selection
Not used
ADF2—Alarm Data Filter
ADF1—Alarm Data Filter
Not used
Alarm Output Enable
Alarm Output Polarity
Alarm Output Line Select
1: ROC is active
0: ROC is inactive
Alarm disable
Alarm source: power supply output
Not used
Not used
Alarm source: auxiliary ADC output
Alarm source: temperature sensor output
Alarm source: INCL_OUT output
Alarm source: INCL_180_OUT output
1: ROC is active
0: ROC is inactive
Alarm disable
Alarm source: power supply output
Not used
Not used
Alarm source: auxiliary ADC output
Alarm source: temperature sensor output
Alarm source: INCL_OUT output
Alarm source: INCL_180_OUT output
1: Use filtered data for comparison
0: Use instantaneous data for comparison
1: Use filtered data for comparison
0: Use instantaneous data for comparison
1: Alarm output enabled
0: Alarm output disabled
1: Active high
0: Active low
1: DIO1
0: DIO0
ADIS16203

Related parts for ADIS16203