DS33R11+ Maxim Integrated Products, DS33R11+ Datasheet - Page 43

IC ETH TXRX T1/E1/J1 256-BGA

DS33R11+

Manufacturer Part Number
DS33R11+
Description
IC ETH TXRX T1/E1/J1 256-BGA
Manufacturer
Maxim Integrated Products
Type
Transceiverr
Datasheet

Specifications of DS33R11+

Protocol
T1/E1/J1
Voltage - Supply
1.8V, 3.3V
Mounting Type
Surface Mount
Package / Case
256-BGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Drivers/receivers
-
9 ETHERNET MAPPER
9.1 Ethernet Mapper Clocks
The DS33R11 clocks sources and functions are as follows:
Clocking of the integrated T1/E1/J1 tansceiver is discussed in Section 10.1. The following table provides the
different clocking options for the Ethernet interface.
Table 9-1. Clocking Options for the Ethernet Interface
RMIIMIIS
1 (RMII)
1 (RMII)
0 (MII)
0 (MII)
0 (MII)
PIN
Serial Transmit Data (TCLKE) and Serial Receive Data (RCLKI) clock inputs are used to transfer data from
the serial interface. These clocks can be continuous or gapped.
System Clock (SYSCLKI) input. Used for internal operation. This clock input cannot be a gapped clock. A
clock supply with ±100ppm frequency accuracy is suggested. A buffered version of this clock is provided
on the SDCLKO pin for the operation of the SDRAM. A divided and buffered version of this clock is
provided on REF_CLKO for the RMII/MII interface.
Packet Interface Reference clock (REF_CLK) input that can be 25MHz or 50MHz. This clock is used as
the timing reference for the RMII/MII interface.
The Transmit and Receive clocks for the MII Interface (TX_CLK and RX_CLK). In DTE mode, these are
input pins and accept clocks provided by an Ethernet PHY. In the DCE mode, these are output pins and
will output an internally generated clock to the Ethernet PHY. The output clocks are generated by internal
division of REF_CLK. In RMII mode, only the REF_CLK input is used.
REF_CLKO is an output clock that is generated by dividing the 100MHz System clock (SYSCLKI) by 2 or
4.
A Management Data Clock (MDC) output is derived from SYSCLKI and is used for information transfer
between the internal Ethernet MAC and external PHY. The MDC clock frequency is 1.67MHz.
100 Mbps
100 Mbps
10 Mbps
10 Mbps
10 Mbps
SPEED
DCE/ DTE
DCE
DCE
DTE
REF_CLKO
OUTPUT
25MHz
25MHz
25MHz
50MHz
50MHz
43 of 344
REF_CLK
±100ppm
±100ppm
±100ppm
±100ppm
±100ppm
25MHz
25MHz
25MHz
50MHz
50MHz
INPUT
Applicable
Applicable
Input from
RX_CLK
(Output)
(Output)
2.5MHz
25MHz
PHY
Not
Not
Applicable
Applicable
Input from
TX_CLK
(Output)
(Output)
2.5MHz
25MHz
PHY
Not
Not
OUTPUT
1.67MHz
1.67MHz
1.67MHz
1.67MHz
1.67MHz
MDC