Page 1
... Without HS7A-DMC79010 10m With HS7A-DMC79110 • Package quantity: 1 • The HS7A-DMC non-contact interlock switch is supplied with an HS9Z-ZC1 actuator . • The contact configuration in the table above shows the contact status when the non-contact interlock switch is not activated . HR1S Safety Relay Modules for • ...
Page 2
... Power A1/A2 Fault LOGIC K1/K2 A2 S21 S22 S23 S41 S42 Guard 2: Closed Guard 4: Closed ESC: External Start Condition Safety Category 4 (EN 954-1) Circuit, HR1S-AF5130B/AF5130PB + HS7A-DMC791 • F1 (protection fuse for the power of safety relay module) L (+) 24V Start Switch ESC A1 S33 S34 S39 T ...
Page 3
... Safety category 3 (EN 954-1) • HR1S-DMB + HS7A-DMC591 (1NO+1NC) + HS9Z-ZC1 F1 (protection fuse for the power of safety relay module) +24V Guard 1: Closed S1.1 Brown + White Black Blue HS7A-DMC S1.2 Brown + White Black Blue Start Switch S1.3 Brown + S3 White ESC Black Blue A1 S11 ...
Page 4
... Be sure to use the HS7A non-contact interlock switch in combina- • tion with the proprietary actuator HS9Z-ZC1 . Do not use other actuators ...
Page 5
... IDEC . Types HS7A Non-contact Interlock Switches • Contact Cable Configura- LED Ordering Type No. Length tion Without HS7A-DMP5002 2m With HS7A-DMP5012 1NO+2NC Without HS7A-DMP5005 5m With HS7A-DMP5015 Without HS7A-DMP7002 2m With HS7A-DMP7012 2NO+1NC Without HS7A-DMP7005 5m With HS7A-DMP7015 • ...
Page 6
... F: Protection fuse for monitor signal contacts (max . 500mA gG (gL Note: The circuit example shown on the left (HR1S-AF and HS7A-DMP70) may not conform to safety cate- gory 4 depending on the operating conditions, such as the frequency of safety function check . Perform risk assessment of your system before operation . 14 ...
Page 7
... Be sure to use the HS7A non-contact interlock switch in combina- • tion with the proprietary actuator HS9Z-ZP1 . Do not use other actuators ...