ISP1161A1BM ST-Ericsson Inc, ISP1161A1BM Datasheet - Page 64

no-image

ISP1161A1BM

Manufacturer Part Number
ISP1161A1BM
Description
IC USB HOST/DEVICE CTRLR 64-LQFP
Manufacturer
ST-Ericsson Inc
Datasheet

Specifications of ISP1161A1BM

Controller Type
USB 2.0 Controller
Interface
Parallel
Voltage - Supply
3.3V, 5V
Current - Supply
47mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
64-LQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
568-1163
ISP1161A1BM,557

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ISP1161A1BM
Manufacturer:
NXP
Quantity:
513
Part Number:
ISP1161A1BM
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
Part Number:
ISP1161A1BMGA
Manufacturer:
EPCOS
Quantity:
6 700
Part Number:
ISP1161A1BMGA
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
Company:
Part Number:
ISP1161A1BMGA
Quantity:
3 000
Part Number:
ISP1161A1BMUM
Manufacturer:
LUMEX
Quantity:
12 000
Part Number:
ISP1161A1BMUM
Manufacturer:
ST-Ericsson Inc
Quantity:
10 000
Philips Semiconductors
9397 750 13961
Product data
Table 35:
Bit
8
7 to 5
4
3
HcRhPortStatus[1:2] register: bit description
Symbol
PPS
-
PRS
POCI
Rev. 03 — 23 December 2004
Description
(read) PortPowerStatus: This bit reflects the port power status,
regardless of the type of power switching implemented. This bit is
cleared if an overcurrent condition is detected.
The HCD sets this bit by writing SetPortPower or SetGlobalPower.
The HCD clears this bit by writing ClearPortPower or
ClearGlobalPower. Which power control switches are enabled is
determined by PowerSwitchingMode.
In the global switching mode (PowerSwitchingMode = 0), only
Set/ClearGlobalPower controls this bit. In per-port power switching
(PowerSwitchingMode = 1), if bit PortPowerControlMask[NDP] for
the port is set, only Set/ClearPortPower commands are enabled. If
the mask is not set, only Set/ClearGlobalPower commands are
enabled.
When port power is disabled, CurrentConnectStatus,
PortEnableStatus, PortSuspendStatus, and PortResetStatus
should be reset.
0 — port power is off
1 — port power is on
(write) SetPortPower: The HCD writes a logic 1 to set
bit PortPowerStatus. Writing a logic 0 has no effect.
Remark: This bit always reads logic 1 if power switching is not
supported.
reserved
(read) PortResetStatus: When this bit is set by a write to
SetPortReset, port reset signaling is asserted. When reset is
completed, this bit is cleared when PortResetStatusChange is set.
This bit cannot be set if CurrentConnectStatus is cleared.
0 — port reset signal is not active
1 — port reset signal is active
(write) SetPortReset: The HCD sets the port reset signaling by
writing a logic 1 to this bit. Writing a logic 0 has no effect. If
CurrentConnectStatus is cleared, this write does not set
PortResetStatus but instead sets ConnectStatusChange. This
informs the driver that it attempted to reset a disconnected port.
(read) PortOverCurrentIndicator: This bit is valid only when the
Root Hub is configured in such a way that overcurrent conditions
are reported on a per-port basis. If per-port overcurrent reporting
is not supported, this bit is set to logic 0. If cleared, all power
operations are normal for this port. If set, an overcurrent condition
exists on this port. This bit always reflects the overcurrent input
signal.
0 — no overcurrent condition
1 — overcurrent condition detected
(write) ClearSuspendStatus: The HCD writes a logic 1 to initiate
a resume. Writing a logic 0 has no effect. A resume is initiated only
if PortSuspendStatus is set.
USB single-chip host and device controller
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.
…continued
ISP1161A1
63 of 136

Related parts for ISP1161A1BM