EP1S30F780I6N Altera, EP1S30F780I6N Datasheet - Page 163

IC STRATIX FPGA 30K LE 780-FBGA

EP1S30F780I6N

Manufacturer Part Number
EP1S30F780I6N
Description
IC STRATIX FPGA 30K LE 780-FBGA
Manufacturer
Altera
Series
Stratix®r
Datasheet

Specifications of EP1S30F780I6N

Number Of Logic Elements/cells
32470
Number Of Labs/clbs
3247
Total Ram Bits
3317184
Number Of I /o
597
Voltage - Supply
1.425 V ~ 1.575 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
780-FBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP1S30F780I6N
Manufacturer:
ALTERA
Quantity:
996
Part Number:
EP1S30F780I6N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP1S30F780I6N
Manufacturer:
ALTERA
0
Altera Corporation
July 2005
While in the factory configuration, the factory-configuration logic
performs the following operations:
The user watchdog timer is a counter that must be continually reset
within a specific amount of time in the user mode of an application
configuration to ensure that valid configuration occurred during a remote
update. Only valid application configurations designed for remote
update can reset the user watchdog timer in user mode. If a valid
application configuration does not reset the user watchdog timer in a
specific amount of time, the timer updates a status register and loads the
factory configuration. The user watchdog timer is automatically disabled
for factory configurations.
If an error occurs in loading the application configuration, the
configuration logic writes a status register to specify the cause of the error.
Once this occurs, the Stratix device automatically loads the factory
configuration, which reads the status register and determines the reason
for reconfiguration. Based on the reason, the factory configuration will
take appropriate steps and will write the remote update control register
to specify the next application configuration page to be loaded.
When the Stratix device successfully loads the application configuration,
it enters into user mode. The Stratix device then executes the main
application of the user. Intellectual property (IP), such as a Nios
ISA) and Nios
device determine when remote update is coming. The Nios embedded
processor or user logic receives incoming data, writes it to the
configuration device, and loads the factory configuration. The factory
configuration will read the remote update status register and determine
the valid application configuration to load.
remote update.
update mode.
Loads a remote update-control register to determine the page
address of the new application configuration
Determines whether to enable a user watchdog timer for the
application configuration
Determines what the watchdog timer setting should be if it is
enabled
®
II (32-bit ISA) embedded processors, can help the Stratix
Figure 3–3
shows the transition diagram for remote
Stratix Device Handbook, Volume 1
Figure 3–2
Configuration & Testing
shows the Stratix
®
(16-bit
3–9

Related parts for EP1S30F780I6N