EP2C5Q208C7 Altera, EP2C5Q208C7 Datasheet - Page 88

IC CYCLONE II FPGA 5K 208-PQFP

EP2C5Q208C7

Manufacturer Part Number
EP2C5Q208C7
Description
IC CYCLONE II FPGA 5K 208-PQFP
Manufacturer
Altera
Series
Cyclone® IIr
Datasheet

Specifications of EP2C5Q208C7

Number Of Logic Elements/cells
4608
Number Of Labs/clbs
288
Total Ram Bits
119808
Number Of I /o
142
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
0°C ~ 85°C
Package / Case
208-MQFP, 208-PQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Number Of Gates
-
Other names
544-1447

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP2C5Q208C7
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2C5Q208C7
Manufacturer:
ALTERA
0
Part Number:
EP2C5Q208C7N
Manufacturer:
ALTERA
Quantity:
45
Part Number:
EP2C5Q208C7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP2C5Q208C7N
Manufacturer:
ALTERA
0
Part Number:
EP2C5Q208C7N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Power-On Reset Circuitry
4–6
Cyclone II Device Handbook, Volume 1
For Cyclone II devices, wake-up time consists of power-up, POR,
configuration, and initialization. The device must properly go through all
four stages to configure correctly and begin operation. You can calculate
wake-up time using the following equation:
Figure 4–3
Figure 4–3. Cyclone II Wake-Up Time
Note to
(1)
The V
characteristics and the power supply used in your system. The fast-on
devices require a maximum V
POR time of 12 ms.
Configuration time will depend on the configuration mode chosen and
the configuration file size. You can calculate configuration time by
multiplying the number of bits in the configuration file with the period of
the configuration clock. For fast configuration times, you should use
Passive Serial (PS) configuration mode with maximum DCLK frequency
of 100 MHz. In addition, you can use compression to reduce the
configuration file size and speed up the configuration time. The t
or t
1
Wake-Up Time = V
V
CC
Minimum
CD2UMC
V
CC
CC
Figure
ramp must be monotonic.
ramp time and POR time will depend on the device
For more information on the t
to the Configuring Cyclone II Devices chapter in the Cyclone II
Device Handbook.
illustrates the components of wake up time.
parameters will determine the initialization time.
Voltage
V
CC
Time
4–3:
Ramp
CC
Ramp Time + POR Time + Configuration Time + Initialization Time
POR Time
CC
ramp time of 2 ms and have a maximum
Configuration Time
CD2UM
or t
CD2UMC
Altera Corporation
parameters, refer
Initialization
Time
February 2007
CD2UM
Mode
User
Time

Related parts for EP2C5Q208C7