MS24149-D1 Leach International, MS24149-D1 Datasheet

no-image

MS24149-D1

Manufacturer Part Number
MS24149-D1
Description
Electromechanical Relay DPDT 10A 28VDC 160Ohm Bracket Mount
Manufacturer
Leach International
Datasheet
CONTACT ELECTRICAL CHARACTERISTICS
Date of issue: 3/06
Contact rating per pole
and load type [1]
Resistive
Inductive [7]
Motor
Lamp
ENGINEERING DATA SHEET
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Featuring
www.esterline.com
APPLICATION NOTES:
101
102
103D
007
LEACH
©
power and control solutions
28 Vdc
10
10
6
2
Balanced armature relay
Hermetically sealed construction
Contact arrangement
Meets the standards and
requirements of
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
Weight
Dimensions max in mm
Special models available upon request
115 Vac
400 Hz
10
10
6
2
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
- 97 -
Load current in Amps
115/200 Vac
400 Hz, 3 Ø
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
10
10
6
2
2 PDT
MIL-PRF-6106
28 Vdc; 115 Vac, 400 Hz, 1 Ø
and 115/200 Vac, 400 Hz, 3 Ø
200 grams max
42.29 x 63.53 x 66.07
RELAY - NONLATCH
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
60 Hz, 1 & 3 Ø [2]
120/208 Vac
10 AMP, 2PDT
1.5
6
4
3
Page 1 of 4
9330

Related parts for MS24149-D1

MS24149-D1 Summary of contents

Page 1

ENGINEERING DATA SHEET APPLICATION NOTES: 101 102 103D 007 CONTACT ELECTRICAL CHARACTERISTICS Contact rating per pole and load type [1] Resistive Inductive [7] Motor Lamp © Featuring LEACH power and control solutions www.esterline.com Data sheets are for initial product selection ...

Page 2

... P/N 9330-10374 has back EMF coil suppression to 42 Vdc. [5] Mounting holes used when replacing AN3311. 6. Applicable Military specification. 28 Vdc MS24149-D1 : Leach Part No. 9330-4026 115 Vac MS24149-A1 : Leach Part NO. 9330-4027 [7] Inductive load life is 20 percent of rated resistive load life. Date of issue: 3/06 ...

Page 3

CONFIGURATION 11.10±0.79 30.16 25.41 66.07 MAX 41.29 25.41 MAX 9.53 STANDARD TOLERANCE: .XXX ± .010 Date of issue: 3/06 MOUNTING STYLE 1 A 37. 20. 54.00 63.53 9330-10374 - 28 VDC ...

Page 4

MOUNTING DATA SCHEMATIC DIAGRAM B2 A2 11.10 ±.79 Date of issue: 3/06 STANDARD TERMINAL LAYOUT MOUNTING DIMENSIONS 30.16 25.41 SIDE MOUNTING STANDARD TOLERANCE: ±.127 - 100 - RAISED TERMINAL MARKING ON PANEL A B ...

Page 5

Application notes DERATING OF CONTACTS FOR DC VOLTAGES To establish a standard for the derating of relay contacts is, at best, a subjective practice. Limitations are governed by the type of relay, contact gap, maximum voltage capabilities of the relay ...

Page 6

... Change in coil resistance due to change of ambient temperature can be calculated by the following formula. "Rule of Thumb" : For each 10°C change of temperature, coil resistance will change approximately 4%. 2. High and low temperature pick up voltage Date of issue: 6/00 RELAYS AND TEMPERATURE VARIATIONS Operating Current Voltage DOWN UP ...

Page 7

Calculation of coil temperature rise when R initial and R final are known: Delta T = (234 Delta T = Temperature rise (° Initial temperature (°C) 1 ...

Page 8

Application notes CURVES FOR DC VOLTAGES ABOVE NORMAL RATING: RESISTIVE LOAD ONLY Date of issue: 6/00 (without arc suppression N°103D Page ...

Page 9

Application notes The inductive nature of relay coils allows them to create magnetic forces which are converted to mechanical movements to operate contact systems. When voltage is applied to a coil, the resulting current generates a magnetic flux, creating mechanical ...

Page 10

Passive devices. The resistor capacitor circuit It eliminates the power dissipation problem, as well as fast voltage rises. With a proper match between coil and resistor, approximate capacitance value can be calculated from 0.02xT/R, where T = operating ...

Page 11

... At the opening time the current becomes constant as a result of practically zero opening speed. Due to this kind of behavior, this type of suppression must be avoided for power relays. For small relays which have to switch low currents of less than 0.2 A, degradation of life is not that significant and the method may be acceptable. ...

Page 12

The diode + resistor network It eliminates the inconvenience of the resistor alone, explained above, and it limits the action of a single diode now preferred to used the diode + zener network. The diode + zener network ...

Related keywords