AD7194BCPZ Analog Devices Inc, AD7194BCPZ Datasheet - Page 28

IC ADC 24BIT SPI 4.8K 32-LFCSP

AD7194BCPZ

Manufacturer Part Number
AD7194BCPZ
Description
IC ADC 24BIT SPI 4.8K 32-LFCSP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7194BCPZ

Data Interface
DSP, MICROWIRE™, QSPI™, Serial, SPI™
Number Of Bits
24
Sampling Rate (per Second)
4.8k
Number Of Converters
1
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 105°C
Mounting Type
Surface Mount
Package / Case
32-WFQFN, CSP Exposed Pad
Resolution (bits)
24bit
Input Channel Type
Pseudo Differential
Supply Voltage Range - Analogue
3V To 5.25V
Supply Voltage Range - Digital
2.7V To 5.25V
Supply
RoHS Compliant
Sampling Rate
4.8kSPS
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
AD7194BRUZ
AD7194BRUZ

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7194BCPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
AD7194
OFFSET REGISTER
RS2, RS1, RS0 = 110; Power-On/Reset = 0x800000)
The offset register holds the offset calibration coefficient for the
ADC. The power-on reset value of the offset register is 0x800000.
The register is a 24-bit read/write register. It is used in conjunc-
tion with the full-scale register to form a register pair. The
power-on reset value is automatically overwritten if an internal
or system zero-scale calibration is initiated by the user. The
AD7194 must be placed in power-down mode or idle mode
when writing to the offset register.
Rev. 0 | Page 28 of 56
FULL-SCALE REGISTER
RS2, RS1, RS0 = 111; Power-On/Reset = 0x5XXXX0
The full-scale register is a 24-bit register that holds the full-scale
calibration coefficient for the ADC. The full-scale register is
a read/write register. However, when writing to the full-scale
register, the ADC must be placed in power-down mode or idle
mode. The register is configured at power-on with a factory
calibrated full-scale calibration coefficient, the calibration being
performed at gain = 1. Therefore, every device has different
default coefficients. The default value is automatically over-
written if an internal or system full-scale calibration is initiated
by the user or if the full-scale register is written to.

Related parts for AD7194BCPZ