4301.5005 Schurter Inc, 4301.5005 Datasheet

MOD PWR ENT 2POS HLDR 10A QC PNL

4301.5005

Manufacturer Part Number
4301.5005
Description
MOD PWR ENT 2POS HLDR 10A QC PNL
Manufacturer
Schurter Inc
Series
KFAr
Type
IEC 320-C14 (Male Pins)r
Datasheets

Specifications of 4301.5005

Current
10A
Features
Fuse Holder
Filter Type
General Purpose
Fuse Drawer
Sold Separately
Mounting Type
Panel Mount, Screw Hole
Termination Style
Quick Connect - .250" (6.3mm)
Voltage
250V
Gender
Plug
Voltage Rating
250VAC
Current Rating
10A
Connector Mounting
Panel
Contact Termination
Quick Connect
No. Of Outlets
1
Connector Type
Filtered / Fused Power Entry
Filtered
Yes
Product
Modules
Housing Material
Thermoplastic
Mounting Style
Screw
Operating Temperature Range
- 25 C to + 85 C
Flammability Rating
UL 94 V-0
Capacitance, Cx
68
Capacitance, Cy
2.2
Color
Black
Current, Leakage
<0.5 mA
Current, Rating
10 A
Cut Out, Panel
33×29 mm
Dielectric Strength
>1.7 kVDC (L-N), >2.7 kVDC (L/N-PE)
Inductance
2×0.3 mH
Material, Housing
Thermoplastic
Mount Method
Front
Number Of Poles
2
Standards
UL Recognized, CSA Certified, VDE and IEC Approved
Temperature, Ambient
-25 to +85 °C
Temperature, Operating
-25 to +85 °C
Termination
Quick Connect
Thickness, Panel
8 mm
Version
Standard
Voltage, Rating
125 VAC (UL/CSA), 250 VAC (IEC) VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
4301.5005
486-1089
Power Entry Modules with Line Filter
Description
- Panel Mount:
Screw-on version from front or rear side, snap-in version from front
- 4 Functions:
Appliance Inlet Protection class I, Fuseholder for fuse-links 5 x 20 mm
- Quick connect terminals or wires
Approvals
- VDE Certificate Number: 40004665 (FKE, FKF, FKV, FKW)
- UL File Number: E72928 (FKE, FKF, FKV, FKW)
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Snap-in mounting from front side
without voltage selector
Fuse drawer must be ordered separately (see
accessories).
IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, optional Voltage Selector (step switch)
side
1- or 2-pole, with or without voltage selector (step switch), Line filter in
standard and medical version
70° C
C14
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 10 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-25 °C to 85 °C
25/085/21 acc. to IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class 1 acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Flexible wire AWG18, 150 mm
Screw: max 8 mm
Mounting screw torque max 0.5 Nm
Snap-in: 0.8 mm to 3 mm
Thermoplastic, black, UL 94V-0
Screw-on mounting from rear side
without voltage selector
EMC Products
Characteristics
- Rear side mounting for efficient costsaving assembly
Suitable for assembly in metal plated plastic housings
- All single elements are already wired
- Plug removal necessary for fuse-link replacement
The fuse drawer “Fingergrip” can be removed by hand
For added safety "Extra-Safe" fuse drawers are available
Fuse drawer meets requirements of medical standard IEC/EN 60601-1
The fuseholder is accessible from the equipment front
- Qualified for use in equipment according IEC/EN 60950
Other versions on request
- Capacity CX 100 nF
References
Alternative: version without line filter KEA
Weblinks
General Product Information, Approvals, RoHS, CHINA-RoHS, Mating
Connectors, e-Store, SCHURTER-Stock-Check, Distributor-Stock-
Check, Accessories, Wire Harness
Appliance-Inlet/-Outlet
Fuseholder
Rated Power Acceptance @
Ta 23 °C
Power Acceptance @ Ta >
23°C
Voltage Selectors
Line Filter
MTBF
Screw-on mounting from front side
with voltage selector
www.schurter.com/pg06
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class 1
1 or 2 pole, Shocksafe category PC2
acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
5 x 20: 2 W (1 pole)/ 1.6 W (2-pole) per
pole
Admissible power acceptance at hig-
her ambient temperature see derating
curves
optional, step, 3 pos.
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 1'700'000 h acc. to MIL-HB-217 F
Plug removal necessary for fuse
replacement
KFA


Related parts for 4301.5005

4301.5005 Summary of contents

Page 1

Power Entry Modules with Line Filter IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole, optional Voltage Selector (step switch) Snap-in mounting from front side without voltage selector Fuse drawer must be ordered separately (see accessories). C14 70° C ...

Page 2

KFA www.schurter.com/pg06 Dimensions Screw-on mounting from front side R6 R3.1 230 R4.5 31 with voltage selector ** without voltage selector Screw-on mounting from rear side 27 44.3 Snap-in mounting 32 ...

Page 3

Power Entry Modules with Line Filter Technical Data of Filter-Components Rated Current Filter-Type [A] 1 Standard Version 2 Standard Version 4 Standard Version 6 Standard Version 10 Standard Version 1 Medical Version (M5) 2 Medical Version (M5) 4 Medical Version ...

Page 4

KFA www.schurter.com/pg06 Attenuation Loss . . . . . 0.1/100Ω differential mode ........... 100/0.1Ω differential mode - - - - differential mode _____ common mode Standard version Medical version (M5 Medical version (M80 Power Entry Modules with Line Filter ...

Page 5

... 4301.5042 - 4301.7012 - 4301.7002 - 4301.5013 3 pos. 4301.5053 - 4301.5003 3 pos. 4301.5043 - 4301.7013 - 4301.7003 - 4301.5014 3 pos. 4301.5054 - 4301.5004 3 pos. 4301.5044 - 4301.7014 - 4301.7004 - 4301.5015 3 pos. 4301.5055 - 4301.5005 3 pos. 4301.5045 - 4301.7015 - 4301.7005 - 4301.6011 - 4301.6001 - 4301.6012 - 4301.6002 - 4301.6013 - 4301.6003 - 4301.6014 - 4301.6004 - 4301.6015 - 4301.6005 - 4301.5201 3 pos. 4301.5241 - 4301.7201 - 4301 ...

Page 6

KFA www.schurter.com/pg06 Rated Current Filter-Type Panel mounting [A] 10 Medical Version (M5) Screw 10 Medical Version (M5) Screw 10 Medical Version (M5) Screw 1 Medical Version (M5) Snap-in 2 Medical Version (M5) Snap-in 4 Medical Version (M5) Snap-in 6 Medical ...

Page 7

Power Entry Modules with Line Filter Cord retaining kits Cord retaining strain relief Flat head, A Countersunk, B Mating Outlets/Connectors Category / Description Appliance OutletOverview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal IEC Appliance Outlet F, ...

Related keywords