DA-033-12-02-00-00 Laird Technologies, DA-033-12-02-00-00 Datasheet

THERMOELECT ASSY DIRECT AIR 32W

DA-033-12-02-00-00

Manufacturer Part Number
DA-033-12-02-00-00
Description
THERMOELECT ASSY DIRECT AIR 32W
Manufacturer
Laird Technologies
Series
DAr
Type
Direct to Air Assemblyr
Datasheet

Specifications of DA-033-12-02-00-00

Voltage
12V
Operating Temperature
-10°C ~ 45°C
Power - Input
37.2W
Heat Transfer Type
Direct to Air
Power - Cooling
32W
Fan Location
Warm Side
Weight
1.19 lbs (539.78g)
Dimensions - Overall
99mm L x 66mm W x 81.5mm H
Cooling Power
32 W
Maximum Current
3.5 A
Maximum Voltage
14.7 V
Height
81.5 mm
Length
99 mm
Width
66 mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Innovative Technology
global
Americas: +1.888.246.9050
Europe: +46.31.704.67.57
Asia: +86.755.2714.1166
CLV-customerservice@lairdtech.com
www.lairdtech.com/thermal
for a Connected World
solutions:
local
support
TM
Tunnel SerieS DirecT-To-Air ThermoelecTric ASSembly
The DA Tunnel Series is a Direct-to-Air thermoelectric assembly (TEA) that minimizes the
number of airflow paths required to operate. It offers dependable, compact performance
by cooling objects via conduction. Heat is absorbed and dissipated through a high density
heat exchanger equipped with an air ducted shroud and a brand name fan. The thermoelectric
modules are custom designed to achieve a high coefficient of performance (COP) to
minimize power consumption. Custom configurations are available, however, MOQ applies.
FeATureS
• Tunnel Series compact design
• Precise temperature control
• Reliable solid-state operation
• DC operation
• RoHS compliant
perFormAnce curve
Specifications
Cooling Power Qcmax (W)
Running Current (A)
Startup Current (A)
Nominal Voltage (V)
Max Voltage (V)
Power Input (W)
Operating Temperature (°C)
Weight (kg)
MTBF (fans – hrs)
Performance Tolerance
DA Tunnel Series, DA-033-12-02
35
30
25
20
15
10
5
0
0
5
10
Thermoelectric Assembly
15
32.0
3.1
3.5
12
14.7
37.2
-10 to 45
0.54
40,000
±10%
20
Qc vs dT
ApplicATionS
• Analytical instrumentation
• Medical diagnostics
• Photonics laser systems
• Industrial instrumentation
• Food and beverage cooling
dT (°C)
25
30
35
40
45
50

Related parts for DA-033-12-02-00-00

DA-033-12-02-00-00 Summary of contents

Page 1

... DA Tunnel Series, DA-033-12-02 Thermoelectric Assembly Tunnel SerieS DirecT-To-Air ThermoelecTric ASSembly The DA Tunnel Series is a Direct-to-Air thermoelectric assembly (TEA) that minimizes the number of airflow paths required to operate. It offers dependable, compact performance by cooling objects via conduction. Heat is absorbed and dissipated through a high density heat exchanger equipped with an air ducted shroud and a brand name fan ...

Page 2

... Laird Technologies materials or products for any specific or general uses. Laird Technologies shall not be liable for incidental or consequential damages of any kind. All Laird Technologies products are sold pursuant to the Laird Technologies’ Terms and Conditions of sale in effect from time to time, a copy of which will be furnished upon request. © ...