PME264NE6100M Kemet, PME264NE6100M Datasheet

no-image

PME264NE6100M

Manufacturer Part Number
PME264NE6100M
Description
Manufacturer
Kemet
Datasheet

Specifications of PME264NE6100M

Capacitance
.1uF
Tolerance (+ Or -)
20%
Voltage
1500VDC/660VAC
Operating Temp Range
-40C to 85C
Mounting Style
Through Hole
Construction
Radial
Failure Rate
Not Required
Product Length (mm)
30.5mm
Product Depth (mm)
15.3mm
Product Height (mm)
22mm
Product Diameter (mm)
Not Requiredmm
Lead Spacing (nom)
25.4mm
Lead Diameter (nom)
1mm
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PME264NE6100MR30
Manufacturer:
EVOX RIFA
Quantity:
6 000
PmE264
• emi suppressor, class x2, metallized paper
• 0.001 – 0.1 µf, 660 vac, +85 °c
• Self-extinguishing encapsulation.
• High dU/dt capability.
• Excellent self-healing properties.
• Good resistance to ionisation due to
High AC and DC voltage applications,
such as
– commutator capacitor in converters
– high voltage DC-capacitor in TV sets
– ignition circuits.
rated voltage
capacitance range
capacitance tolerance
temperature range
climatic category iec
approvals
dissipation factor tanδ
insulation resistance
test voltage between terminals
vibration
Bump
solderability
active flammability
Passive flammability
humidity
Ensures long life even when subjected to
frequent overvoltages.
impregnated dielectric.
tyPiCal aPPliCations
IEC 60068-2-6
Test Fc
IEC 60068-2-29
Test Eb
IEC 60068-2-20
Test Ta
EN 132400
IEC 60384-14
EN 132400
IEC 60068-2-3
Test Ca
tECHniCal data
• The capacitors meet the most
• The impregnated paper ensures
Multi-layer metallized paper. Encapsulated
and impregnated in self-extinguishing
material meeting the requirements of UL
94V-0.
660 VAC 50/60 Hz
1500 VDC
(1600 VDC, + 50°C)
0.001 – 0.1 µF
± 20%
–40 to +85°C
40/085/56/B
ENEC, UL
≤ 1.3 % at 1 kHz
≥ 12000 MΩ
Measured at 500 VDC after 60 s, +23°C
The 100% screening factory test is carried
out at 3000 VDC. The voltage level is
selected to meet the requirements in
applicable equipment standards.
EnvironmEntal tEst data
stringent IEC humidity class, 56 days.
excellent stability giving outstanding
reliability properties, especially in
applications having continuous
operation.
3 directions at 2 hour each,
10 – 500 Hz at 0.75 mm or 98 m/s
4000 bumps at 390 m/s
Solder globule method
+40°C and 90 – 95% R.H.
ConstruCtion
2
2
No visible damage
No open or short circuit
No visible damage
No open or short circuit
Wetting time
for d ≤ 0.8 < 1 s
for d > 0.8 < 1.5 s
56 days
d = 0.8 for p = 15.2 and 20.3
l = standard: 30 +5/-0 mm
1.0 for p = 25.4
option: short leads, tolerance +0/-1 mm
(standard 6 mm, code R06)
Other lead lengths on request
p ± 0.5
L
RoHS
Compliant
B
∅ d


Related parts for PME264NE6100M

PME264NE6100M Summary of contents

Page 1

... PmE264 • emi suppressor, class x2, metallized paper • 0.001 – 0.1 µf, 660 vac, +85 °c • Self-extinguishing encapsulation. • High dU/dt capability. • Excellent self-healing properties. Ensures long life even when subjected to frequent overvoltages. • Good resistance to ionisation due to impregnated dielectric. ...

Page 2

... PME264NB4150MR30 PME264NB4220MR30 PME264NB4330MR30 PME264NB4470MR30 PME264NB4680MR30 PME264NB5100MR30 PME264NC5150MR30 PME264NC5220MR30 PME264NC5330MR30 PME264NE5470MR30 PME264NE5680MR30 PME264NE6100MR30 marKing • RIFA • RIFA article code • Rated capacitance • Rated voltage • X2 • SH, for self healing • Climatic category according to IEC 60068-1, appendix A • Passive flammability class • ...