Appendix 10 System Memory List
A-66
$SW = n
System word memory is allocated to PLC memory as shown below.
Allocated Addresses for System Memory can be displayed by selecting PT – System
Settings in the CX-Designer and clicking the Initial Tab.
Reference
$SW8
$SW9
$SW10
$SW11
$SW12
$SW13
$SW14
$SW15
$SW16
$SW17
$SW18
$SW19
$SW20
$SW21
$SW22
$SW23
$SW24
$SW25
$SW26
$SW27
$SW28
$SW29
$SW30
$SW31
$SW32
$SW33
$SW34
$SW35
$SW36
$SW37
$SW38
$SW39
$SW40
Address
The notification words are not write prohibited. In addition, the system will not restore values,
except when the status has changed.
Notification/control
Notification/control
Notification/control
Control
Control
Notification
Notification
Notification
Notification
Notification
Notification
Notification
Notification
Notification
Notification
Notification
Notification
Control
Control
Control
Control
Control
Control
Control
Control
Control
Control
Notification/control
Notification
Notification
Notification/control
• System memory can be allocated to PLC memory using the same procedure as for
NT-series PTs. For details, refer to 2-4-3 System Memory NT Compatibility in the
NS Series Programming Manual.
Classification
Word n: $SW0
Word n+1: $SW1
Word n+40: SW40
−
−
Pop-up screen 3 display position (X coordinate)
Pop-up screen 3 display position (Y coordinate)
Display label number
Destination (0: Printer/1: Memory Card)
Reserved
Password number for input prohibit clear
Current time (min, s)
Current date and time (day, hour)
Current date (year, month)
Current day (day of the week)
No. of generated alarms and events
ID number for generated alarms and events
ID number for cleared alarms and events
Alarm/event ID when alarm/event object macro executed
Reserved
Macro execution error number
Macro error screen number
Macro error object ID number
Error macro execution timing
Offset value for index I0
Offset value for index I1
Offset value for index I2
Offset value for index I3
Offset value for index I4
Offset value for index I5
Offset value for index I6
Offset value for index I7
Offset value for index I8
Offset value for index I9
Data Log Group Number
Data Block Error Number
Authentication level
Range of initialize Alarm/Event History
Function
Related parts for NS5-MQ10-V2
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
5 Mono Tchsrn,Serial+USB,Bk 60
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
5 Mono ETN,Serial+USB,Bk 60
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
5 STN Color,Serial+USB,Bk 60M
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
5 STN Clr,ETN+Serial+USB,Bk 60
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
5 TFT Clr,Serial+USB,Bk 60M
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
5 TFT Clr,ETN+Serial+USB,Bk 60
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: