2-794620-4 TE Connectivity, 2-794620-4 Datasheet
2-794620-4
Specifications of 2-794620-4
Related parts for 2-794620-4
2-794620-4 Summary of contents
Page 1
... This specification covers performance, tests and quality requirements for the 3 mm Micro MATE-N- LOK* connector family. This connector family has wire-to-board and wire-to-wire configurations. The connectors are available positions in a double row configuration, and positions in a single row configuration, with both configurations using AWG wire. ...
Page 2
... Ratings ! Voltage: 250 volts Current: See Figure 1 for applicable current carrying capability ! Temperature: -40 to 105° C 3.4. Performance and Test Description Product is designed to meet the electrical, mechanical and environmental performance requirements specified in Figure 1. Unless otherwise specified, all tests shall be performed at ambient environmental conditions per EIA-364 ...
Page 3
... EIA-364-52, Category 3 For thru-hole. EIA-638 for surface mount. Subject contacts to solderability. EIA-364-8. Determine crimp tensile at a maximum rate of 25 ± [.98 ± .24 in] per minute. EIA-364-28, Test Condition VII, Condition D. Subject mated specimens to 3.10 G's rms between 20-500 Hz. 15 minutes in each of 3 mutually perpendicular planes ...
Page 4
... EIA-364-32, Test Condition VIII. Subject specimens to 5 cycles between -40 and 105° C. EIA-364-31, Method III. Subject specimens to 10 cycles (10 days) between 25 and 65° 100% RH. EIA-364-17, Method A, Test Condition 4, Test Time Condition C. Subject mated specimens to 105° C for 500 hours. ...
Page 5
... Test omitted when testing wire-to-wire connectors. (d) The fourth test in this sequence will be either humidity/temperature cycling for tin plated specimens or mixed flowing gas for gold plated specimens. Precondition specimens with 10 cycles of durability. Rev D Test Group ( Test Sequence ( 3,7 2,6 3,7 4,8 3 10 Figure 2 108-1836 ...
Page 6
... All test groups shall each consist of a minimum of 5 specimens. B. Test Sequence Qualification inspection shall be verified by testing specimens as specified in Figure 2. 4.2. Requalification Testing If changes significantly affecting form, fit or function are made to the product or manufacturing process, product assurance shall coordinate requalification testing, consisting of all or part of the original testing sequence as determined by development/product, quality and reliability engineering ...
Page 7
Resistance due to X length of wire removed from all readings. NOTE Vibration & Mechanical Shock Mounting Fixture Rev D Figure 3 Termination Resistance Measurement Points Figure 4 108-1836 ...