102PMBS-G1 EDWARDS SIGNALING PRODUCTS, 102PMBS-G1 Datasheet

no-image

102PMBS-G1

Manufacturer Part Number
102PMBS-G1
Description
LAMP, STACKABLE, INDICATOR
Manufacturer
EDWARDS SIGNALING PRODUCTS
Datasheet

Specifications of 102PMBS-G1

Bulb Size
76mm
Supply Voltage
24V
Current Rating
1.75A
Ip/nema Rating
IP65 / NEMA 3R, 4X
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Description
The Edwards Triliptical Stackable Beacon Lighting System is a
unique audible-visual signaling device that can contain up to 5
light modules and either a single or multiple tone module in a
single "stack."
All components of the Triliptical Stackable Beacon Lighting Sys-
tem are UL and cUL listed subassemblies. The units, when as-
sembled, are UL and cUL listed for indoor and outdoor applica-
tions. The enclosures are NEMA 3R, 4X, and IP65 rated. CE
Marked Visual Signal.
The optically designed lenses are available in five colors. See
Table 1. Each lens module contains a removable cover to allow
for easy relamping. The lens module cover features a molded-in
gasket for weather tight reliability.
The unit's bases are available in three models. Two models fea-
ture shorter bases that are used when a lower profile is desired:
one for surface mounting and one for pendant mounting. The
other model features a larger base with a terminal block for use
with an optional horn assembly. The larger base also functions as
a junction box.
A pipe mount kit, Cat. No. 102PMF (sold separately) and one of
three extension pipes (sold separately) allows the status indicator
to be raised above the mounting surface for increased visibility.
It can be used with either the Cat. No. 102TBS or Cat. No.
102PMBS mounting bases.
PLC Compatibility
The electrical input characteristics for PLC compatible signals
are listed in Table 2. Signals with these characteristics may be
directly connected to PLC output cards that do not exceed these
input characteristics.
Installation
Installation must be in accordance with the latest edition of the
National Electrical Code and other governing standards and codes
for standard installation.
1. If using the 102PMF mounting kit, perform the following:
NOTE: All references below are to Figure 4.
Cheshire, CT 06410 203-699-3300 (Ph)
203-699-3365 (Cust. Serv. Fax)
203-699-3078 (Tech. Serv. Fax)
To prevent electrical shock, do not connect power
until instructed to do so.
To prevent abrasion of wiring insulation, ensure
that wire passage holes are adequately protected.
a.
b.
Using the supplied gasket (D) as a guide, mark the four
mounting holes and the center clearance hole on an
appropriate surface.
Punch the four mounting holes. Punch the wiring
clearance hole in the mounting surface to be sufficiently
larger than that in the gasket to ensure the wiring
WARNINGS
Installation Instructions for Triliptical
Stackable Beacon Lighting System
2. Mount the base using one of the following methods:
NOTE: For indoor applications, the base may be panel
3. Connect field wiring.
NOTE: The tone module may be wired to sound independently
c.
d. Ground the flange by pulling the ground wire through
e.
f.
g. Mount the base as instructed below.
a.
b.
c.
a.
b.
c.
insulation is protected from abrasion by the gasket
(without interfering with the mounting screw holes), or
provide other appropriate wire insulation abrasion
protection as needed.
Screw the pipe extension (purchased separately) into the
mounting flange.
the mounting surface clearance hole and center hole of
the gasket. Connect earth ground to the bottom of the
base mount flange using the ground screw (G) and wire
retention terminal cup washer (H).
Pull the remaining field wiring through center clearance
hole of mounting surface, center hole of the gasket, pipe
mount flange and extension pipe.
Align the mounting gasket (D) and flange (A) on the
panel. Secure using (4) #10-24 x 1" (25 mm) pan head
screws (B), (4) external tooth #10 star washers (E) and
(4) #10-24 hex nuts (F).
mounted or conduit mounted. For NEMA3R, 4X, and
outdoor applications, it is recommended that the unit
be conduit mounted vertically facing up using either
the Cat. No. 102TBS or Cat. No. 102PMBS base.
Cat. No. 102TBS Install base on 3/4" (19 mm) conduit
(not supplied). Pull field wiring through conduit entrance
hole.
Cat. No. 102PMBS Install base on 3/4" (19 mm) conduit
(not supplied). Pull field wiring through conduit entrance
hole.
Cat. No. 102DMBS Using the supplied mounting gasket
as a template, punch the four mounting holes. Punch
the wiring clearance hole in the mounting surface to be
sufficiently larger than that in the gasket to ensure the
wiring insulation is protected from abrasion by the gasket
(without interfering with the mounting screw holes), or
provide other appropriate wire insulation abrasion
protection as needed. Mount the base to the surface using
the (2) screws (supplied).
Cat. No. 102TBS Connect field wiring to the terminal
block as shown in Figure 1.
Cat. No. 102PMBS or Cat. No. 102DMBS Using wire
nuts, connect 18" (457 mm) wire leads to field wiring.
The six wire leads are marked as follows: Neutral, 1
Bottom, 2, 3, 4 & 5. 1 Bottom denotes the lead for the
bottom-most signal in the stack.
If using the optional Cat. No. 102SIGST single tone
module or Cat No. 102SIGMT multi-tone module,
connect additional field wiring to the terminal block
mounted on the signal assembly as shown in Figure 2.
or in conjunction with a light signal.
P/N 3100669 ISSUE 1 © 2003
TM

Related parts for 102PMBS-G1

102PMBS-G1 Summary of contents

Page 1

... Cat. No. 102TBS Install base on 3/4" (19 mm) conduit (not supplied). Pull field wiring through conduit entrance hole. b. Cat. No. 102PMBS Install base on 3/4" (19 mm) conduit (not supplied). Pull field wiring through conduit entrance hole. c. Cat. No. 102DMBS Using the supplied mounting gasket as a template, punch the four mounting holes. Punch ...

Page 2

To sound tone module independently, connect to separate hot lead. (2) To sound tone module with a particular light, connect horn hot terminal to selected light terminal on Cat. 102TBS terminal block. 4. Assemble the stackable beacon lighting system ...

Page 3

Maintenance Light Source Replacement 1. Loosen captive screws and remove cover of affected lens module. 2. Remove the light source assembly from the lens module. 3. Install new light source assembly ensuring that the four prongs on the PC board ...

Page 4

... Electrical Catalog No. Ratings Base Units 102TBS-G1 24V DC, 1.75A 102TBS-N5 120V AC, 0.60A 102DMBS-G1 24V DC, 1.75A 102DMBS-N5 120V AC, 0.60A 102PMBS-G1 24V DC, 1.75A 102PMBS-N5 120V AC, 0.60A Optional Pipe Mount Flange 102PMF N/A Optional Extension Pipes 102MP-4 N/A 102MP-10 N/A 102MP-15 N/A Optional Horn Assembly 102SIGST-G1 24V DC, 0 ...

Page 5

Operating Cat. No. voltage* leakage current (mA) 102SIGST-G1 24V DC 102SIGST-N5 120V AC 102SIGMT-G1 24V DC 102SIGMT-N5 120V AC 102LS-SIN-G1 24V DC 102LS-SIN-N5 120V AC 102LS-SINH-G1 24V DC 102LS-SINH-N5 120V AC 102LS-FIN-G1 24V DC 102LS-FIN-N5 120V AC 102LS-FINH-G1 24V DC ...

Related keywords