FPX3-869-20 RADIOMETRIX, FPX3-869-20 Datasheet

no-image

FPX3-869-20

Manufacturer Part Number
FPX3-869-20
Description
MODULE, TRANSCEIVER, 500MW, UHF
Manufacturer
RADIOMETRIX
Datasheet

Specifications of FPX3-869-20

Rohs Compliant
YES
FPX3 is a small, high power (half-watt)
multi-channel wide band FM
transceiver, operating in the Europe-
wide 869.40?869.65MHz sub-band.
High power Multichannel 869MHz band transceiver
Features
Applications
Technical Summary
Evaluation
Radiometrix Ltd
FPX3
Conforms to ETSI EN 300 220-3 and EN 301 489-3
High performance PLL synthesizer
+26dBm RF power output
Data rates up to 20 kbps for standard module
Usable range over 3km
Fully screened. Low profile
Feature-rich interface (RSSI, analogue and digital baseband)
Re-programmable via RS232 interface
Asset tracking systems
Industrial telemetry and telecommand
High performance security system
Fire alarms
ROV control applications
High speed data modems
Operating frequency: 868 – 870MHz
Maximum of 8 channels (depends on band allocation and data rate)
Transmit power: 400mW (+26dBm) nominal
Supply range: +5V regulated
Current consumption: 500mA (at 400mW output) transmit, 50mA receive
Data bit rate: 20kbps max. (standard module)
Receiver sensitivity: -115dBm (for 1KHz/12 dB SINAD)
Size: 67 x 30 x 12mm
Platform: Narrow Band Evaluation Kit
Tel: +44 (0) 20 8909 9595, Fax: +44 (0) 20 8909 2233, www.radiometrix.com
Hartcran House, 231 Kenton Lane, Harrow, Middlesex, HA3 8RP, England
PRELIMINARY
FPX3 Data Sheet (preliminary)
Issue B, 03 November 2010
Figure 1: FPX3-869-20
page 1

Related parts for FPX3-869-20

FPX3-869-20 Summary of contents

Page 1

... Current consumption: 500mA (at 400mW output) transmit, 50mA receive Data bit rate: 20kbps max. (standard module) Receiver sensitivity: -115dBm (for 1KHz/12 dB SINAD) Size 12mm Evaluation Platform: Narrow Band Evaluation Kit Radiometrix Ltd PRELIMINARY FPX3 Data Sheet (preliminary) Issue B, 03 November 2010 Figure 1: FPX3-869-20 page 1 ...

Page 2

... Radiometrix Ltd FPX3 Data Sheet (preliminary) page 2 ...

Page 3

... Both pins must be supplied at all times (most users connect them to a common +5v supply) 7. 10% duty cycle: While the FPX3 is capable of transmitting continuously (the case temperature will rise noticeably) this will be in contravention of the sub-band restrictions. Units operating in the high power 869.4-869.65MHz sub-band are limited to 10% maximum transmit duty cycle ...

Page 4

... Serial data is sent to the unit on the programming input (PGM). To successfully program the unit, it must be powered Unlike earlier Radiometrix multichannel units, the FPX3 has separate N and R registers for each channel, on transmit and on receive. In other words, the frequency of each channel is individually programmed in every mode ...

Page 5

... FM, FSK (F1D, F3D) DC – 10kHz ±16kHz nominal -37dBm <-36dBm 5V pk-pk CMOS data -115dBm for 12dB SINAD at 1KHz -107dBm for <0.1% data errors (20Kbit/sec NRZ) -55dB -80dB -60dB (Tested per. ETSI 300-220-2.3.1) RSSI, Audio, Data FPX3 Data Sheet (preliminary) ο C) page 5 ...

Page 6

... Appendix Radiometrix Ltd [ERP] POWER RF FPX3 Data Sheet (preliminary) page 6 ...

Page 7

... Copyright notice This product data sheet is the original work and copyrighted property of Radiometrix Ltd. Reproduction in whole or in part must give clear acknowledgement to the copyright owner. Limitation of liability The information furnished by Radiometrix Ltd is believed to be accurate and reliable. Radiometrix Ltd reserves the right to make changes or improvements in the design, specification or manufacture of its subassembly products without notice ...