ACPL-W481-500E Avago Technologies US Inc., ACPL-W481-500E Datasheet
ACPL-W481-500E
Specifications of ACPL-W481-500E
Related parts for ACPL-W481-500E
ACPL-W481-500E Summary of contents
Page 1
... Short Maximum Propagation Delays x Minimized Pulse Width Distortion (PWD) x Very High Common Mode Rejection (CMR) x Hysteresis x Available in Stretched SO-6 Package. x Package Clearance/Creepage (ACPL-W481) x Safety Approval: (pending) – UL Recognized with 3750 V ACPL-W481) for 1 minute per UL1577. – CSA Approved. – IEC/EN/DIN EN 60747-5-5 Approved with V 891 V ACPL-W481, under option 060 ...
Page 2
... To order, choose a part number from the part number column and combine with the desired option from the option column to form an ordering part number. Example 1: ACPL-P481-560E: Stretched SO-6 Surface Mount package in Tape and Reel packaging with IEC/EN/DIN EN 60747-5-5 Safety Approval and RoHS compliant. Example 2: ACPL-P481-000E: Stretched SO-6 Surface Mount package in tube packaging and RoHS compliant ...
Page 3
... Recommended Pb-Free IR Profile The recommended reflow profile is per JEDEC Standard, J-STD-020 (latest revision). Non-halide flux should be used. Regulatory Information The ACPL-P481/W481 is pending approval by the following organizations: IEC/EN/DIN EN 60747-5-5 (Option 060 only) Approved with Maximum Working Insulation Voltage V = 891 V ...
Page 4
... Table 1. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (ACPL-P481/W481 Option 060) Description Installation Classification per DIN VDE 0110/1.89, Table 1 for rated mains voltage ≤ 150 Vrms for rated mains voltage ≤ 300 Vrms for rated mains voltage ≤ 600 Vrms Climatic Classification Pollution Degree (DIN VDE 0110/1.89) ...
Page 5
Table 3. Absolute Maximum Ratings Parameter Storage Temperature Operating Temperature Average Input Current Peak Transient Input Current (< pulse width, 300 pps) (< 200 Ps pulse width, < 1% duty cycle) Reverse Input Voltage Average Output Current Supply ...
Page 6
Table 5. Electrical Specifications Over recommended operating conditions T to 0.8 V, unless otherwise specified. All typicals at T Parameter Symbol Logic Low Output Voltage V OL Logic High Output Voltage V OH Output Leakage Current I OHH (V = ...
Page 7
... T <= 5 PA). This test is performed before the 100% production test for partial discharge (Method b) I for any given device. PHL PLH Test Conditions Fig. RH < 50 min 25° 500 V I MHz I < 0 (6000 V for ACPL-W481) for RMS RMS Note > 2 ...
Page 8
I = 6mA F 0.14 0.13 Vcc = 4.5V Vcc = 20V 0.12 0.11 0.1 - TEMPERATURE - °C A Figure 1. Typical Logic Low Output Voltage vs. Temperature 4 -2.6mA 4 3.5 ...
Page 9
T PLH 170 150 130 T PHL 110 - TEMPERATURE - C A Figure 6. Typical Propagation Delays vs. Temperature. 200 T = 25°C A 180 160 T PLH 140 ...