... RoHS 6 fully compliant options available; -xxxE denotes a lead-free product Description The HCPL-7860/HCPL-786J Optically Isolated Modulator and HCPL-0872 Digital Interface IC or digital filter together form an isolated programmable two-chip analog-to-digital converter. The isolated modulator allows direct measure- ment of motor phase currents in power inverters. ...
Page 2
... V Negative input (normally connected to GND1) IN- GND1 Input ground Note connection. Leave floating. Ordering Information HCPL-7860 is UL Recognized with 3750 Vrms for 1 minute per UL1577. HCPL-786J is UL Recognized with 5000 Vrms for 1 minute per UL1577. Option RoHS Non-RoHS Part number Compliant Compliant ...
Page 3
... NOTE: INITIAL OR CONTINUED VARIATION IN THE COLOUR OF THE HCPL-7860/HCPL-786J’S WHITE MOLD COMPOUND ISNORMAL AND DOES NOT AFFECT DEVICE PERFORMANCE OR RELIABILITY. *ALL UNITS WITHIN EACH HCPL-7860 STANDARD PACKAGING INCREMENT (EITHER 50 PER TUBE OR 1000 PER REEL) HAVEA COMMON MARKING SUFFIX TO REPRESENT A REFERENCE VOLTAGE MATCHING OF ± 1%. AN ABSOLUTEREFERENCE VOLTAGE TOLERANCE OF ± ...
Page 4
... DIMENSIONS IN MILLIMETERS AND (INCHES). NOTE: Initial and continued variation in the color of the HCPL-786J's white mold compound is normal and does not affect device performance or reliability. NOTE: FLOATING LEAD PROTRUSION IS 0. mils) MAX. 4 LAND PATTERN RECOMMENDATION 1.016 (0.040) 6.350 ± ...
Page 5
... THE TIME FROM 25˚C to PEAK TEMPERATURE = 8 MINUTES MAX 200˚ 150˚C smax smin Note: Use of non-chlorine-activated fluxes is highly recommended. Regulatory Information The HCPL-7860/HCPL-786J has been approved by the following organizations: IEC/EN/DIN EN 60747-5-2 Approved under: IEC 60747-5-2:1997 + A1:2002 EN 60747-5-2:2001 + A1:2002 DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01. 5 PEAK TEMP ...
Page 6
... Through insulation distance conductor to conductor, usually the straight line distance thickness between the emitter and detector. >175 >175 V DIN IEC 112/VDE 0303 Part 1 IIIa IIIa Material Group (DIN VDE 0110, 1/89, Table 1) HCPL-7860 HCPL-786J Unit III III III 40/85/21 40/85/21 2 ...
Page 7
Absolute Maximum Ratings Parameter Storage Temperature Ambient Operating Temperature Supply Voltages Steady-State Input Voltage Two Second Transient Input Voltage Output Voltages Lead Solder Temperature Solder Reflow Temperature Profile Recommended Operating Conditions Parameter Ambient Operating Temperature Supply Voltages Input Voltage Electrical ...
Page 8
... Matching HCPL-786J V Drift vs. Temperature REF V Drift vs. VDD1 REF Full Scale Input Range Recommended Input Voltage Range DYNAMIC CHARACTERISTICS (Digital Interface IC HCPL-0872 is set to Conversion Mode 3.) Parameter Symbol Signal-to-Noise Ratio SNR Total Harmonic Distortion THD Signal-to-(Noise + Distortion) SND Effective Number of Bits ENOB ...
Page 9
... DD1 intended for customer use. 2. All units within each HCPL-7860 standard packaging increment (either 50 per tube or 1000 per reel) have a Reference Voltage Matching of ± 1%. An Absolute Reference Voltage Tolerance of ± guaranteed between standard packaging increments. 3. Because of the switched-capacitor nature of the isolated modulator, time averaged values are shown. ...
Page 10
Figure 9.4 9.2 9.0 8.8 8.6 8.4 -40 °C 8.2 25 °C 85 ...
Page 11
V = 4.5 V DD1 -100 V = 5.0 V DD1 V = 5.5 V DD1 -150 -40 - TEMPERATURE - °C Figure 7. Offset Change vs. Temperature ...
Page 12
... IN+ V MDAT IN- C2 GND1 GND2 0.1 μF HCPL-7860/ HCPL-786J V IN+ (200 mV/DIV.) OVR1 (200 mV/DIV.) THR1 (2 V/DIV.) 2 μs/DIV CONVERSION MODE # CCLK V DD CLAT CHAN CDAT SCLK 3-WIRE MCLK1 SDAT SERIAL INTERFACE MDAT1 CS + MCLK2 THR1 C3 10 μF MDAT2 OVR1 GND RESET HCPL-0872 ...
Page 13
... HCPL-7860/HCPL-786J can be used together with HCPL- 0872, Digital Interface digital filter. The primary functions of the HCPL-0872 Digital Interface IC are to de- rive a multi-bit output signal by averaging the single-bit modulator data, as well as to provide a direct microcon- troller interface. The effective resolution of the multi-bit output signal is a function of the length of time (measured in modulator clock cycles) over which the average is taken ...
Page 14
... R1 should be chosen to supply sufficient current from the existing floating sup- ply. The voltage from the current sensing resistor or shunt (Rsense) is applied to the input of the HCPL-7860/HCPL- 786J (U2) through an RC anti-aliasing filter (R2 and C2). And finally, the output clock and data of the isolated modulator are connected to the digital interface IC ...
Page 15
PC Board Layout The design of the printed circuit board (PCB) should follow good layout practices, such as keeping bypass capacitors close to the supply pins, keeping output signals away from input signals, the use of ground and power planes, ...
Page 16
For a two-terminal shunt, as the value of shunt resistance decreases, the resistance of the leads becomes a signifi- cant percentage of the total shunt resistance. This has two primary effects on shunt accuracy. First, the effective resis- tance of ...
Page 17
... Shunt Connections The recommended method for connecting the isolated modulator to the shunt resistor is shown in Figure 17. V (pin 2 of the HPCL-7860/HCPL-786J) is connected to the positive terminal of the shunt resistor, while V shorted to GND1 with the power-supply return path func- tioning as the sense line to the negative terminal of the current shunt ...
Page 18
... Voltage Sensing The HCPL-7860/HCPL-786J Isolated Modulator can also be used to isolate signals with amplitudes larger than its recommended input range with the use of a resistive volt- age divider at its input. The only restrictions are that the impedance of the divider be relatively small (less than 1 ...