SHL-W155 Omron, SHL-W155 Datasheet

LIMIT SWITCH

SHL-W155

Manufacturer Part Number
SHL-W155
Description
LIMIT SWITCH
Manufacturer
Omron
Series
SHLr
Type
Basicr
Datasheet

Specifications of SHL-W155

Circuit
SPDT
Switch Function
On-Mom
Contact Rating @ Voltage
10A @ 125VAC
Actuator Type
Lever, Straight
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
235gf
Actuator
Lever
Contact Form
SPDT
Ip Rating
IP 67
Contact Rating
10 Amps at 120 VoltsAC, 240 VoltsAC
Ingress Protection
IP67
Mounting
Chassis
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
SHLW155
Compact, General-purpose Horizontal
Switches.
Models for Microloads Added to Series
• Approved by EN, UL, CSA, and CCC (Chinese standard).
• Incorporates a switch with a durable coil spring in a tough, high-
• Compact and uses a single basic switch for applications where
• Models for microloads and models with operation indicators
• Terminal protective cover can be switched to wire cable from
• Sealing characteristics that meet IEC IP67 degree of protection.
Ordering Information
Switches
Switches (Molded Terminal Models)
Without Operation Indicator, Lead Wired on Right
Without Operation Indicator, Lead Wired on Left
Actuator
Plunger
Panel mount
plunger
Panel mount roller
plunger
Panel mount
crossroller
plunger
Short hinge lever
Hinge lever
SHL-D55-MR
SHL-Q55-MR
SHL-Q2155-MR
SHL-Q2255-MR
SHL-W55-MR
SHL-D55-ML
SHL-Q2155-ML
SHL-Q2255-ML
SHL-W55-ML
SHL-W155-ML
(Ask your OMRON representative for information on approved
models.)
precision case.
strength is required.
added to series.
either the left or right.
Enclosed Switch
SHL
Be sure to read Safety Precautions on page 7 and Safety Precautions for All
Limit Switches.
Model
Model
Type
Standard
Standard
SHL-D55
SHL-Q55
SHL-Q2255
SHL-Q2155
SHL-W55
SHL-W155
Standard
Model
SHL-W155-MR
SHL-W255-MR
SHL-W2155-MR
SHL-W355-MR
SHL-W255-ML
SHL-W2155-ML
Model
Model
SHL-D55-01
SHL-Q55-01
SHL-Q2255-01
SHL-Q2155-01
SHL-W55-01
SHL-W155-01
Micro load
Model
SHL-D55-01MR
SHL-Q55-01MR
SHL-Q2155-01MR
SHL-Q2255-01MR
SHL-W55-01MR
SHL-Q2255-01ML
SHL-W2155-01ML
Note: Models are also available with molded terminals and with molded
Actuator
Short hinge roller
lever
Hinge roller lever
One-way action
short hinge roller
lever
One-way action
hinge roller lever
terminals and operation indicators. Refer to page 6.
Micro load
Model
Model
Type
Micro load
SHL-W255
SHL-W2155
SHL-W355
SHL-W3155
SHL-W255-01MR
SHL-W2155-01MR
Standard
Model
CSM_SHL_DS_E_2_1
Model
SHL-W255-01
SHL-W2155-01
SHL-W355-01
SHL-W3155-01
Micro load
Model
1

Related parts for SHL-W155

SHL-W155 Summary of contents

Page 1

... One-way action SHL-Q2255-01 short hinge roller lever One-way action SHL-Q2155-01 hinge roller lever Note: Models are also available with molded terminals and with molded SHL-W55-01 terminals and operation indicators. Refer to page 6. SHL-W155-01 Model Model SHL-D55-01MR SHL-Q55-01MR SHL-Q2155-01MR SHL-Q2255-01MR SHL-W55-01MR Micro load Model ...

Page 2

... SHL-D55-L2MR SHL-Q2255-L4MR SHL-Q2255-L2MR SHL-W255-L4MR SHL-D55-L3MR SHL-W2155-L4MR SHL-Q55-L3MR SHL-W355-L4MR SHL-Q2155-L3MR Operation Indicator, Lead Wired on Left Standard Model SHL-Q55-LML SHL-W55-L3ML SHL-Q2255-LML SHL-W155-L3ML SHL-W155-LML SHL-W255-L3ML SHL-W255-LML SHL-Q2255-L4ML SHL-W2155-LML SHL-W155-L4ML SHL-Q55-L2ML SHL-Q2255-L3ML Operation Indicator, Lead Wired from Bottom Standard Model SHL-Q2255-LMD SHL-Q2255-L4MD SHL-W255-LMD SHL-W255-L4MD SHL-Q55-L3MD ...

Page 3

... Non-inductive load (A) Rated Resistive load voltage NC NO 125 VAC 0.1 8 VDC 0.1 14 VDC 0.1 30 VDC 0.1 Characteristics (For SHL-W155) Degree of protections Mechanical Durability Electrical Operating speed Mechanical Operating frequency Electrical Rated frequency Insulation resistance Contact resistance Between terminals of the same polarity ...

Page 4

... Operating Position OP 34±0.8 mm Model SHL-Q55 Operating Characteristics SHL-Q55-01 OF max. 9. min. 1. max. 1 min max. 0.5 mm 9.6 FP max. OP 34±0.8 mm Model SHL-Q2255 SHL-Q2255-01 Operating Characteristics OF max. 9. min. 1. max. 1 min max. 0.5 mm 9.6 FP max. OP 43±0.8 mm Model SHL-Q2155 SHL-Q2155-01 Operating Characteristics OF max. 9. min ...

Page 5

... × 15 ± 0.2 16.5 * Stainless sintered roller 9.5 dia. × 4.0 * 6.8 90 ° × 15 16.5 ± 0.2 * Stainless sintered roller SHL Model HL-W155 SHL-W155-01 Operating Characteristics OF max. 2. min. 0. max min max 9.6 FP max. 34 21.5±1 mm SHL-W255 ...

Page 6

... Voltage rating Model Example: Basic type: SHL-Q2255-MR When placing your order for the molded terminal with an LED indicator rated specify the model number as SHL-W2155- L2MR. Contact Circuit SHL How to order Example: Basic type: SHL-Q2255 Location of lead outlet: Right-hand When placing your order for the above ...

Page 7

... Limit Switch with ordinary contact specifications is used. Therefore, when using Limit Switches in the micro-load range, use ones with contact specifications that are suited to each zone. Use the SHL-@-01 micro load models within the zones (1 through 3) shown in the following diagram. ...

Page 8

... SHL 8 ...

Page 9

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords