Page 1
... AC Motor Control £ UPS £ Battery Powered Supplies Ordering Information: Example: Select the complete part module number you desire from the table below -i.e. CM300DY-34A is a 1700V (V CES ), 300 Ampere Dual IGBTMOD™ Power Module. Type Current Rating V CES Amperes ...
Page 2
... Symbol Test Conditions C ies C oes 10V res t d(on 1000V 300A, t d(off) V GE1 = V GE2 = 15V 1.6Ω Inductive Load Switching Operation 300A Symbol CM300DY-34A T j –40 to 150 T stg –40 to 125 V CES 1700 V GES ± 300 Amperes I CM 600 Amperes P C 2900 Watts ...
Page 3
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com CM300DY-34A Dual IGBTMOD™ A-Series Module 300 Amperes/1700 Volts Thermal and Mechanical Characteristics 25°C unless otherwise specified Characteristics Thermal Resistance, Junction to Case Thermal Resistance, Junction to Case Contact Thermal Resistance External Gate Resistance *4 Case temperature ( and heatsink temperature ( measured point is just under the chips. *5 Typical value is measured by using thermally conductive grease of λ ...
Page 4
... Powerex, Inc., 173 Pavilion Lane, Youngwood, Pennsylvania 15697 (724) 925-7272 www.pwrx.com CM300DY-34A Dual IGBTMOD™ A-Series Module 300 Amperes/1700 Volts SWITCHING TIME VS. COLLECTOR CURRENT (TYPICAL 1000V 15V 1.6Ω 125°C d(off) j Inductive Load d(on COLLECTOR CURRENT (AMPERES) C SWITCHING LOSS VS. ...