RMG630302 MERLIN GERIN, RMG630302 Datasheet

RCD, 63A, 30MA, 2POLE

RMG630302

Manufacturer Part Number
RMG630302
Description
RCD, 63A, 30MA, 2POLE
Manufacturer
MERLIN GERIN
Series
RMGr
Datasheet

Specifications of RMG630302

No. Of Poles
2
Voltage Rating Vac
240V
Approval Bodies
IEC/BS
Cross-section Area Max
35mm2
Current Rating
63A
External Depth
70mm
External Length / Height
81mm
External Width
36mm
Tripping
RoHS Compliant
4
Protection earth
leakage
Technical
Section 9
4/2
Dimensions
Section 10
“si” and “SiE” type, A & AC class RCCB
10mA, 30mA, 100mA, 300mA and 500mA
instantaneous 100mAs, 300mAs, 500mAs
Function
Residual current circuit-breakers ensure:
n The control and isolation of electrical circuits
n The protection of persons against direct and indirect contacts
n The protection of installations against insulation faults
They conform to both the residual current device standard BS EN 61008 and to
switch standards BS EN 60947-1 and BS EN 60947-3 . Residual current
circuit-breakers are used in the housing, commercial and industrial sectors .
AC class
Tripping is ensured for sinusoidal, alternating currents, whether they be quickly
applied or slowly increase .
A class
Tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed
DC residual currents, whether they be quickly applied or slowly increase .
Application: loads with electronics, rectifiers, instruments .
“si” type
Reinforced continuity of supply on disturbed networks with:
n A high risk of nuisance tripping:
n Sources of blinding:
“SiE” type
The RCCB “SiE” types are particularly suitable for use in humid environments
and/or environments polluted by aggressive agents, for example swimming pools,
marinas, the food-processing industry, water treatment plants, industrial sites .
They also incorporate RCCB “si” functions .
Instantaneous
It ensures instantaneous tripping (no time-delay) .
Selective s
Total discrimination can be achieved using a non-selective residual current device
placed downstream .
Description
The residual current trip unit is electromechanical . It functions without an auxiliary
source .
Technical data
Voltage rating
Frequency rating
Current rating (Ith) at 40 °C
As in IEC 61008
As in IEC 60947-3:
Successive lightning strokes
IT earthing system
Variable speed controllers, frequency converters
Presence of electronic ballasts
Presence of switchgear that incorporates interference filters i .e . lighting,
microcomputing, etc
Presence of harmonics or high frequency rejection
Presence of DC components: diodes, thyristors, triacs
Low temperature
230…400 V AC, -15…+10 %
AC and A classes: 50/60 Hz
“si” and “SiE” types: 50 Hz
16…100 A
Breaking and making capacity
Isolation with positive break indication, opening is
indicated by a green strip on the device operating
handle . This indicator shows that all poles are open .
Rated impulse withstand
Voltage (Uimp): 6 kV
Insulation voltage (Ui): 440 V
Utilization category:
Rated residual (I∆m): 2 .5 kA
Rated (Im): 1 .5 kA
AC 23A rating ≤ 63 A
AC 22B ratings 80 and 100 A

Related parts for RMG630302

RMG630302 Summary of contents

Page 1

Protection earth leakage 4 Dimensions Technical Section 10 Section 9 4/2 “si” and “SiE” type, A & AC class RCCB 10mA, 30mA, 100mA, 300mA and 500mA instantaneous 100mAs, 300mAs, 500mAs Function Residual current circuit-breakers ensure: n The control and isolation ...

Page 2

Protection earth leakage Dimensions Technical Section 10 Section 9 “si” and “SiE” type, A & AC class RCCB 10mA, 30mA, 100mA, 300mA and 500mA instantaneous 100mAs, 300mAs, 500mAs Description cont.. Padlocking in the “tripped” position is possible using the padlocking ...

Page 3

Protection earth leakage Dimensions Technical Section 10 Section 9 4/4 AC class RCCB 10mA, 30mA, 100mA, 300mA and 500mA instantaneous 100mAs, 300mAs, 500mAs AC class RCCB residual current circuit breakers Type Voltage (V CA) 2P ...

Related keywords