19665 MERLIN GERIN, 19665 Datasheet

RCBO, MCB/RCD, 16A

19665

Manufacturer Part Number
19665
Description
RCBO, MCB/RCD, 16A
Manufacturer
MERLIN GERIN
Datasheet

Specifications of 19665

No. Of Poles
2
Approval Bodies
BS EN60898, BS EN61009
Breaking Capacity Current Ac
6kA
Current Rating
16A
External Depth
75mm
External Length / Height
81mm
External Width
36mm
Mounting Type
DIN Rail
Voltage Rating Vac
240V
Overload Current
6kA
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Type
Comb busbar
1P+N
1P+N
(bag of 2)
25mm
connector (bag of 4)
19668
Type
N + 1P 2
DPN comb busbar 100A/240V IEC664
2
insulated
Width
in
18mm
SP ways
max.13 MCBs
235
N
o
Sens.
(mA)
30
. of MCBs
max.24 MCBs
13
24
432
Rat.
(A)
6
10
16
20
25
32
40
Part n
14880
14890
14885
27
Part N
19661
19663
19665
19666
19667
19668
19669
o
.
10
15
o
.
Comb busbars
Comb busbars enable several circuit breakers to be
supplied with power.
■ The supply to the comb busbar can be connected:
Characteristics
■ Current rating at 40
Clip-on markers
■ Markers can be installed:
Application
Protection against the effects of earth leakage, overload and short circuit currents.
■ 2 pole switching of phase & neutral. Phase
■ Commercial, industrial and domestic electrical
Note: must not be used as the sole means of
providing protection against direct contact (BS7671).
Technical data
■ Nominal voltage: 110/240V
■ Breaking capacity: 6000A Ics to BS EN 60898,
■ Tripping characteristics: C curve: the magnetic
■ Positive contact indication of the phase
■ Sensitivity: (non-adjustable) 30mA:
■ Visual indication of trip due to earth faults
■ AC Class
■ Cable capacities: Tunnel terminals up to 16mm
■ Weight: 190g
■ Installation: Panel mounting on symmetrical DIN
■ Padlocking in the ON/OFF position by using
1 protected pole + switched neutral
R
Directly across the circuit breaker terminals by a
16mm
OR
Via 25mm
MCBs and DPN vigi or combinations of both
100A with a central connector
125A with two supply points
On the front face (max. 6 markers)
Or above the downstream terminals (max. 4
markers).
protected against overloads and short circuits
distribution systems
and earth leakage tested to BS EN 61009
release operates between 5 and 10 In
conductor: in accordance with the IEE Wiring
Regulations BS7671
unwanted tripping: The DPN rcbo incorporates a
filtering device, preventing the risks of unwanted
tripping due to transient voltages (lightning, line
disturbances on other equipment and transient
currents from high capacitive circuits)
rail in multi-service type boards and standard
enclosures
Part N
N
N 2
2
o
. MGLA or 26970
1P
cable
2
connectors. Suitable for use with DPN
0
C:
1P + switched neutral
Combined MCB/RCD
2
DPN RCBO
81