PH100S280-5 TDK Corporation, PH100S280-5 Datasheet - Page 53

no-image

PH100S280-5

Manufacturer Part Number
PH100S280-5
Description
Power Supply, Power Rating 100 Watt, Output Current Rating 20.00 Ampere
Manufacturer
TDK Corporation
Datasheet

Specifications of PH100S280-5

Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PH100S280-5
Manufacturer:
LAMBDA
Quantity:
37
Part Number:
PH100S280-5
Manufacturer:
LAMBDA
Quantity:
492
Part Number:
PH100S280-5
Quantity:
60
(1)Parallel Operation
(2)N+1 Parallel Redundant Operation
・All specifications are subject to change without notice.
PH
1 INTORDUCTION
PH300S, 600S series are applicable to operate in parallel
with an external circuit using CS signal terminal.
There are 2 different kinds of parallel operation.
It is possible to enhance the output when load current can
not be supplied by only one power module or to improve
the reliability by derating the output power of each module.
For power supply that is required high reliability, it is pos-
sible to achieve the requirement by using N+1 units of
power modules for the load of N units.
In N+1 units of parallel operation, even through one of the
power modules is failed the performance of the system
shall be maintained because the other units cover the fail-
ure module and share the load currents.
2 PRECUATIONS
There are several basic cautions and warnings in parallel
operation of PH300S, 600S series.
● Externally attach a control circuit of parallel operation
● Available to use 11 units maximum of power modules in
● Use specified components followed by explanations of
● Set the accuracy of the output voltage within ±1% to
● Set the maximum load current below 95% of sum of the
● Use same length and size of output load lines between
in each power module.
identical model (same output power and voltage.)
basic connection in Instruction Manual at input and out-
put side.
adjust the output voltage.
nominal output current values.
power module and load in parallel connection.
300S, 600S
3. PH300S, 600S Parallel Operation
Figure3-2 Control Circuit fo Parallel Operation
(a)Basic Connection Circuit of Parallel Operation
3 CONNECTION CIRCUIT OF PARALLEL OPEARTION
Basic circuit connection is shown in Figure3-1. For control
circuit of parallel operation, individually connect a circuit
shown in Figure3-2 to each PH300S, 600S series of pow-
er module of parallel operation.
Figure3-1 Basic Connection Circuit of Parallel Operation
Control Circuit of Parallel Operation
Parallel Operation
Control Circuit of
Load
B-351
PH

Related parts for PH100S280-5