PH100S280-5 TDK Corporation, PH100S280-5 Datasheet - Page 52

no-image

PH100S280-5

Manufacturer Part Number
PH100S280-5
Description
Power Supply, Power Rating 100 Watt, Output Current Rating 20.00 Ampere
Manufacturer
TDK Corporation
Datasheet

Specifications of PH100S280-5

Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PH100S280-5
Manufacturer:
LAMBDA
Quantity:
37
Part Number:
PH100S280-5
Manufacturer:
LAMBDA
Quantity:
492
Part Number:
PH100S280-5
Quantity:
60
PH
B-350
PH
  Test must be curried out with direct current.
 Isolation Resistance
Use DC isolation tester (MAX. 500V) to measure the isola-
tion resistance between output and baseplate. The isolation
resistance is more than 100MΩ at 500VDC. Note that some
isolation testers would make high voltage pulse occur when the
applied voltage is varied. Ensure the tester fully discharge after
the test.
Confirm the following items before you think the module is dam-
aged or failed.
1)No Output
2)  High Output Voltage
Figure20-3 Withstand Voltage Test for Output - Baseplate
● Is the rated input voltage supplied?
● Is the remote sensing terminal connected correctly?
● Is the ON/OFF control terminal connected correctly?
● For adjusted output, is the variable resistance network
● Is there any trouble with the connected load?
● Is the remote sensing connected correctly?
● For adjusted output, is the variable resistance network
Figure20-2 Withstand Voltage Test for Input - Baseplate
300S, 600S
set up and connected correctly?
set up and connected correctly?
Withstand
Voltage Tester
4. Before You Think The Module is damaged
Withstand
Voltage Tester
3kVAC 1 minute (20mA)
(48VDC Input Model: 1.5kVAC)
500VDC 1 minute
Baseplate
Baseplate
+Vin
−Vin
CNT
TRM
IOG
+S
+V
−V
−S
CS
 Vibration
Refer to “Installation Application Notes” in the instruction man-
ual.
 Shock
Value is for conditions of our shipping.
 Others
The performance of a system with Power Module is influenced
according to various conditions -- PCBs, chassis, mechanics,
heat dissipation. Please evaluate actual products, and confirm
its performance. (For details, please refer Power Module Appli-
cation Note.)
● Please refer to "Power Module Application Note" for
3)Low Output Voltage
4)Over Load Regulation or Over Input Regulation
5)High Output Ripple  
thermal design and mounting direction.
● Is the rated input voltage supplied?
● Is the remote sensing terminal connected
● Is it measured at sensing point?
● For adjusted output, is the variable resistance
● Is there any trouble with the connected load?
● Is the rated input voltage supplied?
● Are the input and output terminals connected correctly?
● Is it measured at sensing point?
● Are input and output wires too thin?
● Is it same measuring method as the instruction manual?
● Is the input ripple voltage within the specification?
correctly?
network set up and connected correctly?
Isolation
Tester
Figure21-1 Isolation Test
Over 100MΩat 500VDC
・All specifications are subject to change without notice.
Baseplate
+Vin
−Vin
CNT
TRM
IOG
+S
+V
−V
−S
CS

Related parts for PH100S280-5