03595 Simpson, 03595 Datasheet - Page 25

Electromechanical Hour Meter

03595

Manufacturer Part Number
03595
Description
Electromechanical Hour Meter
Manufacturer
Simpson
Type
Elapsed Time Meterr
Datasheets

Specifications of 03595

Time Range
99999.9hr
Power Consumption
2.5W
Supply Voltage Max
120VAC
Time Range Max
99999.9h
Accuracy
Synchronous
Brand/series
Simpson Elapsed Time Meters
Display Type
Digital
Function
Elapsed Time
Material, Casing
Plastic
Mounting Type
Panel
Primary Type
Electromechanical
Range, Measurement
0 to 99999.9
Temperature, Operating
-4°F to +149°F
Voltage, Supply
120 VAC
Indication
99,999.9 Hours
Equipment Type
Elapsed Time Meter
Range
0 - 120
Size
38.1 mm
Lead Free Status / RoHS Status
na
For Use With
AC or DC Powered Equipment
Lead Free Status / RoHS Status
na
• Easily programmed from the front panel
• Remote Reset capability
• Input variety: Quadrature, Switch, TTL,
• Software functions include:
The S663 is a multi-function counter that allows the end user to track the
rate (speed) of a product and continuously monitor the product quantity
for a given process. The count and rate displays have separate pro-
grammable decimal point settings and scaling values.
The counter is powered from 120 or 240VAC and has a non-volatile
EEPROM to retain all programming and count information when the
power source is removed or interrupted. An option 12DCV excitation
output module can provide power for external sensors.
Optional field-replaceable single/dual relay modules enhance the count-
er from a passive display device to an integral control element for your
application. This versatile counter has latching, boundary or timed (0.01
to 599.99 seconds) output modes.
Mounting Requirements
The S660 series 1/8 DIN counters require a panel cutout of 1.77"
(45mm) high by 3.62" (92mm) wide. To install the counter into a
panel cutout, remove the clips from the side of the meter. Slide the
meter through your panel cutout, then slide the mounting clips back
on the meter. Press evenly to ensure a proper fit.
CMOS, NAMUR, PNP, NPN
Password
Set Point Programming
Panel Cutout Dimensions on page A23
Display Scaling
Decimal Point Selection
Specifications
DISPLAY
Type
Height
Decimal Point
Count Direction
Display Range
Output Indicators
POWER REQUIREMENTS
AC Voltages
Power Consumption
INPUT RATINGS
Current Sinking
Current Sourcing
Minimum Pulse Width
Low Pass Filter
Low Bias
High Bias
Count Rate
Maximum Voltage Input
A, B, and User
INPUT
User Input
Standard Input
Quadrature Input
ENVIRONMENTAL
Operating Temp.
Storage Temp.
Relative Humidity
Ambient Temperature
Temp. Coefficient (per °C)
Warmup Time
MECHANICAL
Bezel
Depth
Panel Cutout
Case Material
Weight
Ordering Information
Basic Unit
S663
120 ACV
240 ACV
Power Supply
Standard
Quadrature
1
2
Input
6-digit, 7-segment, red LED
0.56" (14.2mm)
User-programmable
"+" indication implied, "-" indication displayed
-99,999 to +999,999
1 and 2
120, 240VAC, ±10%
3VA
10K , 5% Resistor pull-up to (9.0 - 16DCV) ±10%
5.1K , 5% Resistor pull-down to common
~5µs
<200Hz
VLT = 1.6V ±10% VUT = 3.6V ±10%
VLT = 5.0V ±10% VUT = 7.0V ±10%
20KHz (Pulse Max) 5KHz (Quadrature X4 Max)
30DCV (Max)
(Rate channel reset) Count on the rate channel
is reset when the User Input is pulled low.
VLT
VLT
0°C to +40°C
-10 °C to +60°C
0-80% non-condensing for temperatures less
than 32°C, decreasing linearly to 50% at 40°C
25°C
±100ppm/ °C
15 minutes
3.93" x 2.04" x .52" (99.8mm x 51.8mm x 13.2mm)
3.24" (82.3mm)
3.62" x 1.77" (92mm x 45mm)
PBT-ABS
9oz (255.1g)
None
One Relay
Two Relays
0.2 DCV guaranteed low, VUT = 3.0 DCV(max)
0.9 DCV VUT =3.15 DCV (max)
1
2
Output
(100mA Max Current)
0
1
2
Excitation
12DCV
None
None
Other
0
1
0
21
A

Related parts for 03595