S701E15N3S EATON CUTLER HAMMER, S701E15N3S Datasheet

Motor Starter

S701E15N3S

Manufacturer Part Number
S701E15N3S
Description
Motor Starter
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of S701E15N3S

No. Of Phases
Three
Power Rating
10hp
Current Rating
15A
Peak Reflow Compatible (260 C)
No
Output Current
15A
Supply Voltage Max
415VAC
Control Voltage Max
480V
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Description
The S701 device is a reduced voltage soft start series control-
ler designed to control acceleration and deceleration of three-
phase motors. The S701 provides the user the ability to adjust
initial torque, ramp up and down time, and also select kick start
for high inertia loads.
Approvals
CAN. CSA-C22.2 / UL Std. No. 508
IEC 947-4-2, IEC 158-2,
EN 60947-4-2, HD 419.2-S1
CE Marked
Mounting Guidelines
Important — The S701_15, and S701_25 controllers are
designed for vertical mounting in free air. If these controllers
are mounted horizontally, the load current must be reduced to
50% of rated current.
DO NOT INSTALL OR PERFORM MAINTENANCE ON THIS
DEVICE WHILE EQUIPMENT IS ENERGIZED. DEATH OR
SEVERE PERSONAL INJURY CAN RESULT FROM CON-
TACT WITH ENERGIZED EQUIPMENT. VERIFY THAT NO
VOLTAGE IS PRESENT BEFORE PROCEEDING WITH
INSTALLATION OR MAINTENANCE.
Only qualified persons, as defined in the National Electric
Code, who are familiar with the installation, maintenance and
operation of this device and the equipment onto which it is to
be installed, as well as applicable local, state and national reg-
ulations and industry standards and accepted practices
regarding safety of personnel and the equipment safety should
be permitted to install, maintain or operate this device. These
instructions are provided only as a general guide to such quali-
fied persons and are not all-inclusive. They do not cover every
application or circumstance which may arise in the installation,
maintenance or operation of this equipment. Users are advised
to comply with all local, state and national regulations and
industry standards and accepted practices regarding safety of
personnel and equipment.
REMOVE ALL POWER FROM THE INSTALLATION
BEFORE ATTEMPTING TO INSTALL OR REMOVE THIS
DEVICE. THIS INCLUDES L1, L2, L3 AS WELL AS A1, A2,
11 AND 12.
Effective 01/02
WARNING
CAUTION
Instruction Leaflet for S701 Soft Starters
Dimensions, mm [inches]
Figure 1. Approx. Dimensions in mm [inches] — S701_03
Figure 2. Approx. Dimensions in mm [inches] — S701_15
Figure 3. Approx. Dimensions in mm [inches] — S701_25
Figure 4. Approx. Dimensions in mm [inches] — Mounting
22,5 [0.89]
[1.18]
8,5 [0.33]
30
30,0 [1.2]
[1.77]
30,0 [1.2]
45,0
45,0
1.77
90 [3.54]
[1.18]
30
[0.33]
8,5
8,5 [0.33]
[0.17 ]
S701_15 & S701_25
4,3 [0.17]
horizontal mounting
3,5 [0.14]
4,3
rating reduction for
Can be mounted
Requires 50%
in any position
S701_03
127,3 [5.01]
123,8 [4.87]
120 [4.72]
[5.04 ]
128,1
[4.72 ]
120
128 [5.04]
120 [4.72]
80 [3.15]
Pub 49440
[0.15]
[0.15 ]
3,8
3,8
1

Related parts for S701E15N3S

S701E15N3S Summary of contents

Page 1

... Instruction Leaflet for S701 Soft Starters Description The S701 device is a reduced voltage soft start series control- ler designed to control acceleration and deceleration of three- phase motors. The S701 provides the user the ability to adjust initial torque, ramp up and down time, and also select kick start for high inertia loads ...

Page 2

... VA Item No. Item No. Item No. (3.5 Amp) (15 Amp) (25 Amp) S701C03N3S S701C15N3S S701C25N3S S701D03N3S S701E15N3S S701E25N3S S701E03N3S S701E15N3S S701E25N3S S701G03N3S S701G15N3S S701G25N3S Adjustable from 0 seconds Adjustable from 0 seconds Adjustable from 0 – 85% of nominal torque Control Options S - Standard BP - Aux. Contact Line Voltage C - 208-240 V AC Number of Poles ...

Page 3

Current Derating Operation in ambient temperatures exceeding 40°C [104°F] is possible if the power dissipation is limited either by reducing the steady-state current or by reducing the duty cycle of the soft starter as shown in Table 6. Table 6. ...

Page 4

Pub 49440 Using Line Voltage Control S701 C1 When the contactor C1 is switched to the ON state, the motor controller will soft start the motor according to the set- tings of the ramp-up time and ...

Page 5

S701E25N3S 92EQ10005A0001A J 0 8,2 0,8 Ramp up 5 3,9 2,7 Ramp down 0 8,2 0 1,8 3,9 2,7 Initial torque ...

Page 6

Pub 49440 6 Effective 01/02 ...

Page 7

Effective 01/02 Pub 49440 7 ...

Page 8

Pub 49440 © 2002 Eaton Corporation All Rights Reserved Printed in USA Effective 01/02 ...