QS30 Series Diffuse-Mode Laser Sensor
8
SETUP mode is used to change sensor output response for:
• Light or Dark operate
• 30-millisecond pulse stretcher (OFF delay), if required.
The status LEDs, active only during SETUP mode, indicate the output response
configuration when the sensor will be in RUN mode. Four combinations are possible:
To access SETUP mode and change the output response settings:
1)
2)
3)
NOTES: • If SETUP mode programming is interrupted and remains inactive for 60
Use during RUN mode, accomplished via push buttons only.
Two-Point TEACH (Static or Dynamic):
Single-Point TEACH:
The lighted bargraph LEDs move to reflect the increase or decrease.
In addition to its programming function, Remote Programming may be used to disable
the push buttons for security. Disabling the push buttons prevents undesired tampering
with the programming settings. Connect the gray wire of the sensor as described on
page 4, and four-pulse to either enable or disable the push buttons:
SETUP Mode
Manual Adjust
Push Button Disable
P/N 109027 rev. C
Press and hold BOTH push buttons (or double-pulse Remote line) until the
green LED indicator turns OFF.
Click EITHER push button (or pulse Remote line) to toggle through the four
possible setting combinations.
Press and hold both push buttons (or hold Remote line) until the green LED
indicator turns ON, indicating return to RUN mode.
Light Operate, No Delay
Dark Operate, No Delay
Dark Operate, 30 ms Delay
Light Operate, 30 ms Delay
• SETUP mode operates in the “background”, while the outputs are active.
• Fine-tunes sensing threshold set-point value
• Press “+” to increase; press “-” to decrease
• Adjusts sensing window size (tolerance) for the single-point target
• Press “+” to increase; press “-” to decrease
seconds, the sensor returns to RUN mode with the most recent settings
(i.e., exits and saves current selection).
condition
T
T
T
T
T
T
T
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
Figure 5. SETUP mode
Indicators
SETUP
Status
{
Minneapolis, MN U.S.A.
Press and
hold
both push
buttons
to access
SETUP
mode