QS30LDL BANNER ENGINEERING, QS30LDL Datasheet - Page 6

Photoelectric Sensor

QS30LDL

Manufacturer Part Number
QS30LDL
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of QS30LDL

Output Current
150mA
Sensor Output
NPN/PNP
Supply Voltage Range Dc
10V To 30V
Sensor Housing
Rectangular
Sensor Input
Laser
Body Material
ABS Plastic
Supply Voltage Max
30VDC
Sensing Range Max
800mm
QS30 Series Diffuse-Mode Laser Sensor
Dynamic TEACH is best used when a machine or process may not be stopped for
teaching. A variation of two-point TEACH, it programs the sensor during actual
machine run conditions, taking multiple samples of the light and dark conditions and
automatically setting the threshold at the optimum level (see Figure 3).
Dynamic TEACH activates the sensor’s adaptive threshold system, which continuously
tracks minimum and maximum signal levels, and automatically maintains centering of
the switch point between the light and dark conditions. The adaptive threshold system
remains in effect during RUN mode. The adaptive routine saves to non-volatile
memory at least once per hour.
When Dynamic TEACH mode is used, the Output ON state (light or dark operate) will
remain as it was last programmed. To change the Output ON state, use SETUP mode
(see page 8).
The sensing set point may be adjusted (fine-tuned) whenever the sensor is in RUN
mode by clicking the “+” and “-” buttons. However, when a manual adjustment is
made, the adaptive threshold system is disabled (cancelled).
6
Dynamic TEACH and Adaptive Thresholds
• Teach on-the-fly
• Sets a single switching threshold
• Threshold position is adjustable using “+” and “-” buttons (Manual Adjust)
P/N 109027 rev. C
• Press and Hold
• Present Output
• Continue to hold
• Release
ON and OFF
conditions
Push Button
• Hold remote line
• Present Output ON
• Continue to hold
• Release remote
low (to ground)
and OFF conditions
remote line low (to
ground)
line/switch
Remote Line
Power LED: OFF
Bargraph: #7 & 8 flashing
Power LED: OFF
Bargraph: #7 & 8 flashing
Teach Accepted
Power LED: ON
Bargraph: One LED flashes to show
Sensor returns to RUN mode with
new settings
Teach Unacceptable
Power LED: OFF
Bargraph: #1, 3, 6, 8 flash to show fail
Sensor returns to RUN mode
without changing settings
relative contrast (good contrast
shown; see table above)
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
Display Shows
Figure 3. Two-Point Dynamic TEACH
(no signal)
Bargraph
Number
Darkest
6 to 8
4 to 5
2 to 3
LED
1
Darkest Taught
Condition
Output OFF
(Light Operate shown)
Excellent: Very stable operation.
Good: Minor sensing variables will
not affect sensing reliability.
Low: Minor sensing variables will
affect sensing reliability.
Marginal: Consider an alternate
sensing scheme.
between taught conditions
Minneapolis, MN U.S.A.
threshold midway
Sensor positions
Manual Adjust
adjusted by
Relative Contrast/
Recommendation
Position
Output ON
Lightest Taught
Condition
Most Light
(saturated
signal)