Page 1
... Note: 1. When ordering, add the rated coil voltage to the model number. Example: G6S-2F 12 VDC Rated coil voltage 2. When ordering tape packing, add -TR" to the model number. Example: G6S-2F-TR 12 VDC Tape packing Be sure since -TR" is not part of the relay model number not marked on the relay case. Model Number Legend ...
Page 2
... The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. Double-winding Latching Type (G6SK-2, G6SK-2F, G6SK-2G) Rated voltage 4.5 VDC Rated current 44 ...
Page 3
... G6S Single-side Stable EN60950/EN41003 Approved Type (G6S-2-Y, G6S-2F-Y, G6S-2G-Y) Rated voltage 5 VDC Rated current 40 mA 125 Ω Coil resistance Must operate voltage 75% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 170% of rated voltage at 23°C Power consumption Approx. 200 mW Note: 1. The rated current and coil resistance are measured at a coil temperature of 23° ...
Page 4
... Approved Standards ■ UL1950 (File No. E41515)/CSA C22.2 No.950 (File No. LR31928) Model G6S-2, G6S-2F, G6S-2G DPDT G6SU2, G6SK-2, G6SU-2F, G6SU2G, G6SK-2F, G6SK-2G EN60950/EN41003 Model G6S-2-Y, G6S-2G-Y, G6S-2F-Y DPDT 74 Contact form Coil ratings 1 VDC 1 VDC Contact form Isolation category Supplementary Isolation G6S ...
Page 5
... Time (s) Ambient Temperature vs. Maximum Coil Voltage Single-side Stable 12 VDC max. 24 VDC (G6S-Y, 12 VDC max.) 24 VDC (G6S-Y) Ambient temperature (°C) Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Single-winding Latching Double-winding Latching G6SU 12 VDC max ...
Page 6
... G6S Dimensions Note: All units are in millimeters unless otherwise indicated. Single-side Stable G6S-2, G6S-2-Y Tolerance: ±0.3 G6S-2F, G6S-2F-Y Tolerance: ±0.3 G6S-2G, G6S-2G-Y Tolerance: ±0.3 76 Footprint Terminal Arrangement/ (Bottom View) Internal Connections (Bottom View) Tolerance: ±0.1 Eight, 1-dia. holes Orientation mark Footprint ...
Page 7
... View) Tolerance: ±0.1 Eight, 1-dia. holes Footprint (Top View) Tolerance: ±0.1 7.3+0.2 Footprint 7.3+0.2 (Top View) Tolerance: ±0.1 G6S Terminal Arrangement/ Internal Connections (Bottom View) Orientation mark Terminal Arrangement/ Internal Connections (Top View) Orientation mark Terminal Arrangement/ Internal Connections (Top View) ...
Page 8
... Footprint (Bottom View) Tolerance: ±0.1 Ten, 1-dia. holes Footprint (Top View) Tolerance: ±0.1 Footprint 7.3+0.2 (Top View) Tolerance: ±0.1 G6S Terminal Arrangement/ Internal Connections (Bottom View) Orientation mark Terminal Arrangement/ Internal Connections (Top View) Orientation mark Terminal Arrangement/ Internal Connections (Top View) ...
Page 9
... Use a DC power supply with 5% or less ripple factor to operate the coil. Do not use the G6S where subject to strong external magnetic fields. Do not use the G6S where subject to magnetic particles or exces- sive amounts of dust. Do not reverse the polarity of the coil (+, − ). Latching types are delivered in the reset position. We recommend that a reset voltage be applied in advance to start operation ...
Page 10
... G6S ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K093-E1-03 80 G6S ...