B57820M102A3 EPCOS Inc, B57820M102A3 Datasheet - Page 10

THERMISTOR DISC 1K OHM 5%

B57820M102A3

Manufacturer Part Number
B57820M102A3
Description
THERMISTOR DISC 1K OHM 5%
Manufacturer
EPCOS Inc
Series
B57820r
Type
NTCr
Datasheet

Specifications of B57820M102A3

Resistance In Ohms @ 25°c
1K
Resistance Tolerance
±5%
B Value Tolerance
±1.5%
B25/100
3560K
Operating Temperature
-55°C ~ 155°C
Power - Max
180mW
Mounting Type
Clamp On
Package / Case
Coin Type, 5.1mm Dia x 2.2mm W
Resistance
92 Ohms
Tolerance
5 %
Termination Style
SMD/SMT
Operating Temperature Range
- 55 C to + 155 C
Power Rating
180 mW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
B0/50
-
B25/50
-
B25/75
-
B25/85
-
Lead Length
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
495-2139
B57820M 102A 3
B57820M0102A003
Mounting
Operation
This listing does not claim to be complete, but merely reflects the experience of EPCOS AG.
Please read Cautions and warnings and
Important notes at the end of this document.
Temperature measurement and compensation
Leadless NTCs
Ensure that no thermo-mechanical stress occurs due to production processes (curing or
overmolding processes) when thermistors are sealed, potted or overmolded or during their
subsequent operation. The maximum temperature of the thermistor must not be exceeded.
Ensure that the materials used (sealing/potting compound and plastic material) are chemically
neutral.
Electrodes/contacts must not be scratched or damaged before/during/after the mounting
process.
Contacts and housing used for assembly with the thermistor must be clean before mounting.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of the thermistor. Be sure that surrounding parts and materials can
withstand the temperature.
Avoid contamination of the thermistor surface during processing.
The connections of sensors (e.g. cable end, wire end, plug terminal) may only be exposed to
an environment with normal atmospheric conditions.
Tensile forces on cables or leads must be avoided during mounting and operation.
Bending or twisting of cables or leads directly on the thermistor body is not permissible.
Avoid using chemical substances as mounting aids. It must be ensured that no water or other
liquids enter the NTC thermistors (e.g. through plug terminals). In particular, water based
substances (e.g. soap suds) must not be used as mounting aids for sensors.
Use thermistors only within the specified operating temperature range.
Use thermistors only within the specified power range.
Environmental conditions must not harm the thermistors. Only use the thermistors under
normal atmospheric conditions or within the specified conditions.
Contact of NTC thermistors with any liquids and solvents should be prevented. It must be
ensured that no water enters the NTC thermistors (e.g. through plug terminals). For
measurement purposes (checking the specified resistance vs. temperature), the component
must not be immersed in water but in suitable liquids (e.g. Galden).
Avoid dewing and condensation unless thermistor is specified for these conditions.
Bending or twisting of cables and/or wires is not permissible during operation of the sensor in
the application.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage
caused by malfunction.
Page 10 of 13
B57820M
M820